![Belfort AWOS Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/belfort/awos/awos_maintenance-manual_2725781010.webp)
-7-
BELFORT
INSTRUMENT
Proprietary Information
5.1
D
ATU
–
D
ATA
A
CQUISITION
T
ERMINAL
U
NIT
M
AINTENANCE
Any defects observed or detected during these tests must be described and recorded on the
Facility Maintenance log, FAA Form 6030-1.
5.1.1 DATU
T
RI
-
ANNUAL
M
AINTENANCE
1. Clean air filters with hand-held vacuum cleaner.
2. Clean cabinets with mild detergent and water (wring cloth dry).
3. Check the computer CPU Power Supply cooling fans to assure they are operating and listen
for any unusual noise such as; grinding or squealing, that would indicate the fan is not
functioning properly. The DATU computer is not a field repairable item. Therefore, if the fan
is not operating or is making unusual noise, contact Belfort to arrange for computer
replacement or factory repair.
3a. Check PC Clock for accurate time and Atomic Clock operation. If the time is not accurate,
then perform the Atomic clock verification procedure in Appendix G. Then reset the Windows
clock through the windows control panel to the correct time.
3b. Download and install any Windows Updates indicated by the Windows OS.
**The Belfort AWOS tower should be powered up with both AC and DC Circuit breakers
on. Some of the sensors take up to 5 minutes for their averaged values to be reported to the
DATU from the DCP.
4. The Belfort AWOS Tower transmits telemetry, system status, sensor status and data quality
status along with weather data. Advisor software captures the telemetry and displays it on the
Advisor Main screen. See Figure 1a below.
Содержание AWOS
Страница 17: ... 14 BELFORT INSTRUMENT Proprietary Information Figure 2a Securing the Tower for Maintenance ...
Страница 49: ... 46 BELFORT INSTRUMENT Proprietary Information Figure 9 Temperature Humidity Sensor Removal ...
Страница 51: ... 48 BELFORT INSTRUMENT Proprietary Information Figure 10 Visibility Sensor Removal ...
Страница 60: ...BELFORT INSTRUMENT Proprietary Information Appendix A Belfort AWOS Maintenance Forms ...
Страница 66: ...BELFORT INSTRUMENT Proprietary Information This page intentionally left blank ...
Страница 71: ...BELFORT INSTRUMENT Proprietary Information Appendix B Belfort AWOS Tri Annual Annual 5 Year Maintenance Plan ...
Страница 74: ...BELFORT INSTRUMENT Proprietary Information Appendix C UHF Transceiver Specifications ...
Страница 76: ...BELFORT INSTRUMENT Proprietary Information Appendix D Standard Unicom Radio ICOM A110 VHF Radio Specifications ...
Страница 88: ...BELFORT INSTRUMENT Proprietary Information Appendix F DCP Site Configuration Procedure ...
Страница 93: ...BELFORT INSTRUMENT Proprietary Information Appendix G Belfort AWOS Atomic Clock Verification Procedure ...