-29-
BELFORT
INSTRUMENT
Proprietary Information
Belfort AWOS Alert Messages
1. Contact FBO for an important message.
2. Wind speed sensor INOP.
3. Wind direction sensor INOP.
4. Temperature and/or humidity sensor INOP.
5. Barometric pressure sensor INOP.
6. Belfort AWOS being serviced. Do not use readings.
7. Belfort AWOS not maintained. Do not use readings.
8. Private Belfort AWOS weather station. Do not use.
9. Landing area warning
0. No Alerts
Figure 6
Belfort AWOS Alert Messages
4)
Document the failure in the Facility Maintenance Log on the FAA Form 6030-1.
5)
Follow any other rules or requirements required by the airport authority or the FAA.
6)
Notify the Belfort Factory for any technical assistance, repair RMA or replacement parts.
6.0
T
ROUBLESHOOTING
T
HE
S
YSTEM
If any corrective action is taken during any troubleshooting in this section, the work must be
reported in the Facility Maintenance Log on FAA forms 6030-1.
6.1
S
YSTEM
B
UILT
–I
N
D
IAGNOSTICS AND
T
ROUBLESHOOTING
The Belfort AWOS Tower transmits system status, sensor status and data quality status along with
weather data. Advisor software captures this data and compares it to the last status received. If
there is a difference in any of the data, the software writes all the data to the Advisor Status Log
and to the Advisor Current Status Page. At any time, the maintenance technician can view the most
recently received Status Information displayed in a user-friendly format. The maintenance
technician can also view the Status Change History for past or recurrent problems. Refer to the
“Belfort AWOS Operator’s Instruction Manual” for complete instructions for using the Advisor
software.
If the Belfort AWOS DATU becomes inoperative or problems are evident with the computer or
monitor, verify that all cable connections are secure and that system power is present. If these
checks do not return the equipment to normal operation, contact Belfort Instrument Co. customer
support to make arrangements to have the computer replaced. There are no other troubleshooting
procedures for the DATU or Belfort AWOS software.
If the DATU has developed a fault,
Follow the Belfort AWOS System Component Failure
Instructions in Section 5.10.
A summary of the current condition indicators and status log indicators is shown below:
Status Pages are reached by selecting “Status Pages” on the Advisor main menu.
Содержание AWOS
Страница 17: ... 14 BELFORT INSTRUMENT Proprietary Information Figure 2a Securing the Tower for Maintenance ...
Страница 49: ... 46 BELFORT INSTRUMENT Proprietary Information Figure 9 Temperature Humidity Sensor Removal ...
Страница 51: ... 48 BELFORT INSTRUMENT Proprietary Information Figure 10 Visibility Sensor Removal ...
Страница 60: ...BELFORT INSTRUMENT Proprietary Information Appendix A Belfort AWOS Maintenance Forms ...
Страница 66: ...BELFORT INSTRUMENT Proprietary Information This page intentionally left blank ...
Страница 71: ...BELFORT INSTRUMENT Proprietary Information Appendix B Belfort AWOS Tri Annual Annual 5 Year Maintenance Plan ...
Страница 74: ...BELFORT INSTRUMENT Proprietary Information Appendix C UHF Transceiver Specifications ...
Страница 76: ...BELFORT INSTRUMENT Proprietary Information Appendix D Standard Unicom Radio ICOM A110 VHF Radio Specifications ...
Страница 88: ...BELFORT INSTRUMENT Proprietary Information Appendix F DCP Site Configuration Procedure ...
Страница 93: ...BELFORT INSTRUMENT Proprietary Information Appendix G Belfort AWOS Atomic Clock Verification Procedure ...