274
KAYENNE K-FRAME — Installation & Service Manual
Appendix A — Specifications
Table 35. Kayenne Control Panel Mechanical Specifications
Component
Depth
Width
Height
Weight
a
a
All weights approximate.
Rack Units
Control Panels
Curved Support Structure Orientation
4 ME-35, with attached
Local Aux Stripe, 15 m Cables
746.3 mm
(29.38 in.)
1533.7 mm
(60.38 in.)
559.3 mm
(22.02 in.)
58 kg
(127 lbs.)
n/a
3 ME-35, with
Local Aux Stripe, 15 m Cables
637.1 mm
(25.08 in.)
1533.7 mm
(60.38 in.)
292.3 mm
(11.51 in.)
45 kg
(99lbs.)
n/a
2 ME-25, with
Local Aux Stripe, 15 m Cables
488.4 mm
(19.23 in.)
1341.7 mm
(52.82 in.)
242.3 mm
(9.54 in.)
30 kg
(66 lbs.)
n/a
1 ME-15,with 15 m Cables,
without Local Aux Stripe
356.4 mm
(14.03 in.)
758.3 mm
(29.85 in.)
84.3 mm
(3.32 in.)
15 kg
(33 lbs.)
n/a
Local Aux Stripe
Separately Mounted, Flat Orientation
Local Aux-35
with 15 m Cable
185.7 mm
(7.31 in.)
813.7 mm
(32.04 in.)
84.3 mm
(3.32 in.)
6 kg
(14 lbs.)
n/a
Local Aux-25
with 15 m Cable
185.7 mm
(7.31 in.)
621.7 mm
(24.48 in.)
84.3 mm
(3.32 in.)
6 kg
(14 lbs.)
n/a
Menu Panel
Touch Screen
with 15 m cable
91.7 mm
(3.612 in.)
417.85 mm
(16.45 in.)
270.10 mm
(10.63 in.)
6 kg
(14 lbs.)
n/a
Menu Panel Support Arm
n/a
n/a
n/a
5 kg
(11 lbs)
n/a
Panel Control Unit (PCU)
588.52 mm
(23.17 in.)
482.60 mm
(19 in.)
132.59 mm
(5.22 in.)
16 kg
(36 lbs)
3
Table 36. PCU Interconnects
Control Panel - PCU Connections
Cable and connectors
Custom 7 Pin D style
Number Required
1 for each Control Panel Stripe, Local Aux Stripe, and Satellite Panel
Max. Interconnect Cable Length
15 m / 50 ft. (7.5 m / 25 ft. cable length also available)
Cable Weight
15 m / 50 ft.
1.3 kg (2.9 lbs)
7.5 m / 25 ft.
0.7 kg (1.6 lbs.)
Touch Screen Menu Panel - PCU Connection
Cable and connectors
Custom 17 Pin D style
Number Required
1 for each Menu Panel (2 maximum)
Max. Interconnect Cable Length
15m / 50ft (7.5m / 25ft cable length also available)
Cable Weight
15 m / 50 ft.
1.6 kg (3.7 lbs)
7.5 m / 25 ft.
0.9 kg (2.0 lbs.)
Table 37. Power
Panel Control Unit (required for Control Panel and Touch Screen Menu Panel Operation)
Line voltage
100V-240V AC +/-10% autorange, power factor corrected. Automatic line-
voltage sensing for 120V and 240V sources.
Line frequency
50/60Hz +/- 5%
Power consumption
max. 500W
Leakage current
< 2.5 mA
Содержание Grass Valley Kayenne K-Frame
Страница 2: ......
Страница 30: ...30 KAYENNE K FRAME Installation Service Manual Regulatory Notices ...
Страница 42: ...42 KAYENNE K FRAME Installation Service Manual Section 1 Introduction ...
Страница 108: ...108 KAYENNE K FRAME Installation Service Manual Section 4 System Cabling ...
Страница 175: ...KAYENNE K FRAME Installation Service Manual 175 Configuration File Save and Load Figure 121 Files Ops User Setups Menu ...
Страница 186: ...186 KAYENNE K FRAME Installation Service Manual Section 5 Basic Configuration Figure 126 PGM Output Assigned to Suite 2 ...
Страница 208: ...208 KAYENNE K FRAME Installation Service Manual Section 5 Basic Configuration ...
Страница 270: ...270 KAYENNE K FRAME Installation Service Manual Maintenance ...