An external router can be configured into
levels
, to allow the switching of multiple signals
simultaneously. For example, video signals can be organized on one level, and key signals
on another. By specifying both levels when giving a router take command, both the video
and key signals of a source will be routed to their destinations.
Router control panels can also
protect
router destinations from being changed by other
control panels. A protected router destination cannot be changed by a different control
panel, but may be changed by the panel that set the protection. Protections help prevent
inappropriate router source changes. The GV Switcher system can be considered a type of
router control panel, and so the GV Switcher system can protect router destinations. GV
Switcher system router protect commands are applied to all router levels.
The names of router sources appear on the GV Switcher system source name displays.
These names originate from the router system, and their text cannot be changed from the
GV Switcher system. If a routed source has no connection to the router, an
X
appears in
place of the router source name. If the router connection exists, but no source has yet been
selected for that destination (which can occur during bootup),
No Src
appears.
Features
• Interfaces to the Grass Valley SMS 7000 routing system.
• GV Switcher system configuration of routed sources.
• Names of router sources are shown on GV Switcher Control Panel source name displays.
• Router source selection control via the Control Panel, and Menu Panel.
• Protection types (None, Protect, Protect All, and On Air).
• R-MEM control.
Menu Panel Router Interface Operation
The Router Control menu provides a way to directly change router sources from the Menu
Panel. The Router Select menu is reached by pressing the
R-MEM
Menu Panel button, then
selecting the
Router Control
category selection button.
Note:
GV Switcher system router take commands are only applied to all
router levels.The external routing system’s destinations must be
configured with all router levels selected.
Note:
Router interface operation becomes available after the GV
Switcher system and the external router have been properly configured.
See the Installation & Service Manual for your switcher model for
additional information.
Содержание Grass Valley GV Korona
Страница 16: ...xvi Table of Contents Index 425 Contact Us 433...
Страница 32: ...32 Introduction Supported Control Protocols...
Страница 40: ...40 Panel Preferences Map Remote Aux Panel Delegation Buttons Logical Mapping...
Страница 61: ...61 Kayenne Karrera GV Korona User Manual Update a Show File 1 Select File Ops Show Files...
Страница 72: ...72 Suite Preferences Load User Setups...
Страница 266: ...266 Device Control Newton Channel Information...
Страница 330: ...330 Advanced Operations Corner Pinning Menus Select the eDPM mode button lower left eDPM Corner Pinning...
Страница 432: ...432 Index...