am.book : ch22 69 Tue May 6 13:24:47 1997
22-69
Chapter 22 Annex Parameters
Annex Manager User Guide
Part 5 Reference Information
output
_start_char
defines the control character sequence that restarts output if
output_flow_control
is set to
start/stop
.
output
_stop_char
defines the control character sequence that stops output if
output_flow_control
is set to
start/stop
.
output_ttl
sets the time-to-live (TTL) for packets the Annex generates for RIP updates.
TTL is a field in IP packets that limits their lifetime on the network. Each time
a packet crosses a router, the router decrements the packet TTL by 1. When the
value reaches 0, the packet is discarded.
parity
defines the type of parity that the asynchronous port uses.
Type
Async
Value
+ any character
Default
+
(displays as ^Q)
Lists
Async Port, Flow Control
Ctrl
Ctrl
Q
Type
Async
Values
+ any character
Default
+
(displays as ^S)
Lists
Async Port, Flow Control
Ctrl
Ctrl
S
Type
Annex
Values
1 to 255
Default
64
Lists
Annex Only, Routing
Type
Async
Values
none, odd, even
Default
none
Lists
Async Port, Basic Async Port, Modem, Modem Internal
Содержание Manager
Страница 10: ...am book amTOC doc x Tue May 6 13 24 47 1997 Annex Manager User Guide Contents x ...
Страница 14: ...am book amLOF doc xx Tue May 6 13 24 47 1997 Annex Manager User Guide Figures xx ...
Страница 16: ...am book amLOT doc xxii Tue May 6 13 24 47 1997 Annex Manager User Guide Tables xxii ...
Страница 22: ...am book pref xxviii Tue May 6 13 24 47 1997 Annex Manager User Guide Preface xxviii ...
Страница 118: ...am book ch5 10 Tue May 6 13 24 47 1997 Annex Manager User Guide Chapter 5 Setup Mode Basics 5 10 Part 2 Setup Mode ...
Страница 168: ...am book ch10 4 Tue May 6 13 24 47 1997 Annex Manager User Guide Chapter 10 Setting SNMP Traps 10 4 Part 2 Setup Mode ...