am.book : ch21 12 Tue May 6 13:24:47 1997
Annex Manager User Guide
Chapter 21 Annex Manager and SNMP
21-12
Part 4 Control and Status Commands
RFC 1317 RS-232 MIB Restrictions
The Annex supports this MIB with the restrictions described in
Table 21-5
.
Table 21-5. RFC 1317 RS-232 MIB Objects
Object Name
Restrictions
Read Object
Limitations
rs232PortInSpeed
rs232PortOutSpeed
Setting one sets both.
Can set only to a
supported value. See
Setting Port Speed
below.
None
rs232AsyncPortParity
none (1)
,
mark (4),
or
space (5)
all map to
none (1)
Returns only
none (1)
,
odd (2)
, or
even (3)
rs232AsyncPortStopBits
dynamic (4)
maps to
one (1)
Returns only
one
(1), two (2)
, or
one-and-half (3)
rs232SyncPortClockSource
Accepts
external (2)
only
Returns
internal (1)
or
external (2)
rs232SyncPortInterrupted
Frames
Not supported
None
rs232SyncPortAborted
Frames
Not supported
None
Содержание Manager
Страница 10: ...am book amTOC doc x Tue May 6 13 24 47 1997 Annex Manager User Guide Contents x ...
Страница 14: ...am book amLOF doc xx Tue May 6 13 24 47 1997 Annex Manager User Guide Figures xx ...
Страница 16: ...am book amLOT doc xxii Tue May 6 13 24 47 1997 Annex Manager User Guide Tables xxii ...
Страница 22: ...am book pref xxviii Tue May 6 13 24 47 1997 Annex Manager User Guide Preface xxviii ...
Страница 118: ...am book ch5 10 Tue May 6 13 24 47 1997 Annex Manager User Guide Chapter 5 Setup Mode Basics 5 10 Part 2 Setup Mode ...
Страница 168: ...am book ch10 4 Tue May 6 13 24 47 1997 Annex Manager User Guide Chapter 10 Setting SNMP Traps 10 4 Part 2 Setup Mode ...