1.6
Hydraulic safety
When making the hydraulic connection, it is imperative that the standards
and corresponding local directives be respected.
If radiators are connected directly to the heating circuit: install a differential
valve between the indoor module and the heating circuit.
Fit drainage valves between the indoor module and the heating circuit.
Do not add any chemical products to the heating water without first
consulting a water treatment specialist. For example: antifreeze, water
softeners, products to increase or reduce the pH value, chemical additives
and/or inhibitors. These may cause faults in the heat pump and damage
the heat exchanger.
1.7
Recommendations for the installation
Install the heat pump's indoor module in a frost-free location.
Insulate the pipes to reduce heat losses to a minimum.
Apply refrigerant oil to the beaded parts to facilitate tightening and improve
the seal.
Keep this document close to the place where the appliance is installed.
Do not make any modifications to the heat pump without the written
consent of the manufacturer.
To benefit from extended warranty cover, no modifications should be
made to the appliance.
Install the heat pump indoor module and outdoor unit on a solid, stable
structure able to bear its weight.
Do not install the heat pump in a place that has an atmosphere with a high
salt content.
Do not install the heat pump in a place exposed to steam and combustion
gases.
Do not install the heat pump in a place that may be covered in snow.
1.8
Recommendations for operation
The frost protection function does not work if the heat pump is switched
off.
If the home is unoccupied for a long period and there is a risk of frost,
drain the indoor module and the heating system.
Keep the heat pump accessible at all times.
Never remove or cover the labels and data plates affixed to appliances.
Labels and data plates must be legible throughout the entire lifetime of the
appliance.
Immediately replace damaged or illegible instructions and warning
stickers.
Give preference to the OFF or frost protection mode rather than switching
off the system to leave the following functions running:
Anti blocking of pumps
Frost Protection
Regularly check the presence of water and pressure in the heating
system.
Do not touch radiators for long periods. Depending on the heat pump
settings, the temperature of the radiators may exceed 60°C.
Do not drain the installation, except in cases of absolute necessity. E.g.:
several months' absence with the risk of temperatures in the building
falling below freezing.
1 Safety instructions and recommendations
7654506 - v06 - 19112019
9