Product name
Platinum BC
iPlus V200
Smart 4.5
Platinum BC
iPlus V200
Smart 6
Platinum BC
iPlus V200
Smart 8
Declared capacity for heating for part load at an in
door temperature of 20 °C and outdoor temperature
T
j
T
j
= -7 °C
Pdh
kW
2.6
3.3
5.0
T
j
= +2 °C
Pdh
kW
2.7
2.1
3.0
T
j
= +7 °C
Pdh
kW
3.3
2.0
3.6
T
j
= +12 °C
Pdh
kW
2.6
2.7
4.4
T
j
= bivalent temperature
Pdh
kW
3.1
3.9
5.7
T
j
= operation limit temperature
Pdh
kW
3.1
3.9
5.7
Bivalent temperature
T
biv
°C
-10
-10
-10
Cdh
—
1.0
1.0
1.0
Seasonal space heating energy efficiency under
average conditions
ƞ
s
%
125
126
126
Seasonal space heating energy efficiency under
colder conditions
ƞ
s
%
109
116
119
Seasonal space heating energy efficiency under
warmer conditions
ƞ
s
%
156
150
155
Declared coefficient of performance or primary en
ergy ratio for part load at an indoor temperature of
20 °C and outdoor temperature
T
j
T
j
= -7 °C
COPd
-
1.74
1.73
2.04
T
j
= +2 °C
COPd
-
3.32
3.21
3.03
T
j
= +7 °C
COPd
-
4.38
4.63
4.60
T
j
= +12 °C
COPd
-
6.35
7.24
6.19
T
j
= bivalent temperature
COPd
-
1.42
1.58
1.72
T
j
= operation limit temperature
COPd
-
1.42
1.58
1.72
Operation limit temperature for air-to-water heat
pumps
TOL
°C
-10
-10
-10
Heating water operating limit temperature
WTOL
°C
55
60
60
Electrical power consumption
Off mode
P
OFF
kW
0.016
0.013
0.015
Thermostat-off mode
P
TO
kW
0.017
0.013
0.015
Stand-by
P
SB
kW
0.016
0.012
0.015
Crankcase heater mode
P
CK
kW
0.000
0.000
0.045
Supplementary heater
Rated heat output
Psup
kW
0.0
0.0
0.0
Type of energy input
Electricity
Electricity
Electricity
Other specifications
Capacity control
Variable
Variable
Variable
Sound power level, indoors - outdoors
L
WA
dB
30 – 55
35 – 57
34 – 61
Annual energy consumption under average con
ditions
Q
HE
kWh
1934
2501
3568
Annual energy consumption under colder condi
tions
Q
HE
kWh
4483
3721
4621
Annual energy consumption under warmer condi
tions
Q
HE
kWh
1173
1394
2029
Rated air flow rate, outdoors for air-to-water heat
pumps
—
m
3
/h
2680
2700
3300
Declared load profile
L
L
L
Daily electricity consumption
Q
elec
kWh
3.670
3.770
4.030
Annual electricity consumption
AEC
kWh
769
787
833
3 Technical specifications
16
7654506 - v06 - 19112019