Parameter
Description
Unit
EHC–06
SCB-04
AC008
Thermal energy delivered for central heating
kWh
X
AC009
Thermal energy delivered for domestic hot water
kWh
X
AC010
Thermal energy delivered for cooling
kWh
X
AC013
Seasonal COP
X
AC026
Counter that shows the number of pump running
hours
hours
X
AC027
Counter that shows the number of pump starts
-
X
AC028
Number of operating hours of the first electrical
backup stage
hours
X
AC030
Number of starts of the first electrical backup
stage
-
X
DC002
Numbers of Domestic Hot Water diverting valve
cycles
-
X
DC003
Number of hours during which the diverting valve
is in DHW position
hours
X
DC004
Number of compressor start-ups during domestic
hot water production
X
DC005
Number of compressor start-ups
X
PC003
Number of compressor operating hours
hours
X
CODE
Enter the installer code to access the following pa
rameters.
X
AC002
Number of hours that the appliance has been
producing energy since last service
hours
X
AC003
Number of hours since the previous servicing of
the appliance
hours
X
AC004
Number of heat generator starts since the
previous servicing.
X
AC013
Seasonal coefficient of performance
X
SERVICE
Resetting the maintenance service
CLR: the AC002, AC003, and AC004 counters are
reset to zero.
X
7.4.2
COUNTERS, TIME PROG, CLOCK \CIRCA, CIRCB
and DHW menus
Tab.63
Menu
Description
CIRCA
TP.H: Timer programming for heating
06:00 - 23:00 ON
23:00 - 06:00 OFF
TP.C: Timer programming for cooling
14:00 - 23:00 ON
23:00 - 14:00 OFF
CIRCB
TP.H: Timer programming for heating
06:00 - 23:00 ON
23:00 - 06:00 OFF
TP.C: Timer programming for cooling
14:00 - 23:00 ON
23:00 - 14:00 OFF
DHW
Timer programming for domestic hot water
06:00 - 23:00 ON
23:00 - 06:00 OFF
7 Settings
7654506 - v06 - 19112019
81