Operating conditions
Instruction handbook
b maXX
5000
Document No.: 5.09021.16
Baumüller Nürnberg GmbH
52
3.3
3.3.5.3 Correction values input voltage
Above
rated power
supply voltage
m
Mains rectifier units BM503X, BM504X, BM517X, BM519X
The rated power supply voltage is 3 x 400 V
The output currents must be reduced accordingly when operating with a power supply
voltage higher than 400 V.
Ou
tp
ut
c
urr
ent
180 V
400 V
528 V
100 %
50 %
Power supply voltage
Figure 21:
Derating: Output current as a function of the power supply voltage
The device draws the rated/peak current at rated supply voltage. The input current must
be reduced if power supply voltage is higher than 400 V and the DC link output power re-
mains constant.
Input curr
ent [%]
Supply voltage [V]
Peak current
Max. continuous
current
Figure 22:
Derating: Input current BM503X, BM504X, BM517X, BM519X
Содержание b maXX 5000
Страница 101: ...Design and Operation Instruction handbook b maXX 5000 Document No 5 09021 16 101 of 328 4 ...
Страница 220: ...Fieldbus communication Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 220 of 328 8 4 ...
Страница 240: ...Error handling Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 240 of 328 10 4 ...
Страница 298: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 298 of 328 A ...
Страница 299: ...299 of 328 Operation Manual b maXX 5000 Document no 5 09021 16 APPENDIX B DECLARATION OF CONFORMITY ...
Страница 324: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 324 of 328 Table of Figures ...
Страница 328: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 328 of 328 Notes ...
Страница 329: ......