Troubleshooting and Fault correction
Instruction handbook
b maXX
5000
Document No.: 5.09021.16
237
10
10.3 Error detection
10.3.1 BM50XX error detection
The error state is signalized by the lighting up of the red LEDs H1 to H4 on the front side
of the housing.
The meaning of the individual LEDs is explained in
Display and operating elements
from page 90 for devices without safety function and
LED display BM5030 with safety
as from page 306 for devices with safety function.
10.3.2 BM51XX and BM53XX error detection
LED
The error state is signalized by the lighting up of the red LED H14 or H24 on the front side
of the housing.
The meaning of the individual LEDs is explained in
Essentially, the lowest red LEDs H14 and H24 „Malfunction“ are of significance here.
NOTE!
In case of warnings or errors without error reactions, the LEDs H14 or H24
blink
„Malfunction“. Only error messages with error reaction are signalized by
constant
lighting up
.
7-segment display
In the status error the error numbers are shown in the display. Depending on the state of
bit No. 16 in parameter
P135.1
(further information see parameter handbook
b maXX
5000
) all error messages (with/without error reaction) or warnings are displayed.
The display of an error code starts therewith, that „F“ is displayed for 1.5 s. Then the four
characters of the error code are displayed. The separate characters are displayed for
about 0.8 s, interrupted by a short break. If there are other errors, these are displayed in
the same manner. The procedure is repeated as soon as all errors were displayed.
Example: Error 702 and 2418 are detected:
Start
End Time
Error
display
Figure 102:
7-segment display: errors and warnings
For further information on the subjects of error messages and error numbers, see „Pa-
rameter manual
b maXX
5000
„.
Содержание b maXX 5000
Страница 101: ...Design and Operation Instruction handbook b maXX 5000 Document No 5 09021 16 101 of 328 4 ...
Страница 220: ...Fieldbus communication Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 220 of 328 8 4 ...
Страница 240: ...Error handling Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 240 of 328 10 4 ...
Страница 298: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 298 of 328 A ...
Страница 299: ...299 of 328 Operation Manual b maXX 5000 Document no 5 09021 16 APPENDIX B DECLARATION OF CONFORMITY ...
Страница 324: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 324 of 328 Table of Figures ...
Страница 328: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 328 of 328 Notes ...
Страница 329: ......