8.4
Fieldbus communication
Depending on the version of
b maXX 5000
as from page 84) different fieldbus systems are provided.
8.4.1
EtherCAT
®
.
Type code
b maXX 5000
with EtherCAT
®
:
BM5XXX-XXXX-XXXX-
01
XX-
CoE profile (CANopen
®
over EtherCAT
®
)
BM5XXX-XXXX-XXXX-
07
XX-
SoE profile (Servodrive profile over EtherCAT
®
)
Data can be transmitted to and from other nodes (e. g. from the EtherCAT
®
master) via
the
b maXX 5000
with EtherCAT
®
slave.
X3
and
X4
on the front side of the device are the RJ45 connections for the EtherCAT
®
-
Front side of active mains rectifier BM51XX
Mounting and
installation
.
The mounting/installation consists of the following steps:
1
De-energize the
b maXX 5000
device
2
Set the
b maXX 5000
IP-address,
see
Setting the IP address with address switches
3
Connect
b maXX 5000
with Ethernet-connection cables.
n
Please, observe an EMC-compatible laying of the Ethernet connection cables!
n
The following cables were released for use by Baumüller:
Ethernet-connection cable;
Further information see
Commissioning
.
The following preconditions must be fulfilled before commissioning:
1 b maXX 5000
with EtherCAT
®
is installed correctly.
n
Ethernet-connection cables are wired correctly.
2
The control cabinet is properly locked and all safety devices are operating.
3
The
b maXX 5000
device is ready-to-use.
Address switch
By means of the address switches S1 to S4 the IP-address is set
(Refer to settings
Setting the IP address with address switches
Further information about the setting possibilities of the EtherCAT
®
slave see „Application
Manual“.
Содержание b maXX 5000
Страница 101: ...Design and Operation Instruction handbook b maXX 5000 Document No 5 09021 16 101 of 328 4 ...
Страница 220: ...Fieldbus communication Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 220 of 328 8 4 ...
Страница 240: ...Error handling Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 240 of 328 10 4 ...
Страница 298: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 298 of 328 A ...
Страница 299: ...299 of 328 Operation Manual b maXX 5000 Document no 5 09021 16 APPENDIX B DECLARATION OF CONFORMITY ...
Страница 324: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 324 of 328 Table of Figures ...
Страница 328: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 328 of 328 Notes ...
Страница 329: ......