![Baumuller b maXX 5000 Скачать руководство пользователя страница 85](http://html.mh-extra.com/html/baumuller/b-maxx-5000/b-maxx-5000_instruction-handbook-manual_2711361085.webp)
Design and Operation
Instruction handbook
b maXX
5000
Document No.: 5.09021.16
85
4
BM5XXX-XX
X
X-XXXX-XXXX-XX-XXXX
SAF modules (BM53XX only) / STO function (BM5030 only)
0: No SAF module / no STO function
1: BM5030 with STO function, basic type with feedback outputs
2: BM5030 with STO function, automatic locking function
refer to
Appendix C - BM5030 with Safety Function
BM5-O-SAF
A: -000-000-001
SAF module standard without parameter memory
B: -000-000-000
SAF module with parameter memory
C: -001-000-000
STO controllable via I/O, with parameter memory,
without automatic restart
D: -001-000-002
STO controllable via I/O, with parameter memory,
with automatic restart
E: -002-000-000
STO controllable via I/O and FSoE, with parameter
memory, with daisy-chain inputs, without separated grounds,
with 12h encoder test
F: -002-001-000
STO controllable via I/O and FSoE, with parameter
memory, without daisy-chain inputs,
without separated grounds, with 12h encoder test
G: -003-000-000
STO controllable via I/O and FSoE, with parameter
memory, with daisy-chain inputs, without separated grounds,
with 12h encoder test
H: -003-001-000
STO controllable via I/O and FSoE, with parameter
memory, without daisy-chain inputs,
without separated grounds, with 12h encoder test
I: -001-001-000
STO controllable via I/O, without parameter memory,
with automatic restart, with short-circuit test
K: -001-001-001
SS1 controllable via I/O (SS1 time is a fixed set value),
without parameter memory, with automatic restart,
with short-circuit test
BM5XXX-XXX
X
-XXXX-XXXX-XX-XXXX
Power unit design
BM50XX, BM51XX
0: X1 inhibit input expects NO contact, refer to
1: X1 inhibit input expects NC contact, refer to
error reset via power supply off
power supply on, refer to
BM532X
2: With motor brake, instruction handbook 5.09021.03 is valid
3: Without motor brake, instruction handbook 5.09021.03 is valid
4: With motor brake, 3-pole motor connector, PE screw terminals
5: Without motor brake, 3-pole motor connector, PE screw terminals
BM533X to BM537X
2: With motor brake
3: Without motor brake
BM5XXX-XXXX-
XX
XX-XXXX-XX-XXXX
Encoder evaluation
00: None
01: Encoder 1 and Encoder 2:
HIPERFACE
®
, EnDat
®
2.1, SSI, square and sine incremental encoder, resolver
02: Encoder 1 and Encoder 2: EnDat
®
2.2
03: Encoder 1 and Encoder 2: HIPERFCACE DSL
®
06: Encoder 1: refer to 01, Encoder 2: EnDat
®
2.2
07: Encoder 1: refer to 01, Encoder 2: HIPERFCACE DSL
®
08: Encoder 1: EnDat
®
2.2, Encoder 2: refer to 01
Содержание b maXX 5000
Страница 101: ...Design and Operation Instruction handbook b maXX 5000 Document No 5 09021 16 101 of 328 4 ...
Страница 220: ...Fieldbus communication Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 220 of 328 8 4 ...
Страница 240: ...Error handling Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 240 of 328 10 4 ...
Страница 298: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 298 of 328 A ...
Страница 299: ...299 of 328 Operation Manual b maXX 5000 Document no 5 09021 16 APPENDIX B DECLARATION OF CONFORMITY ...
Страница 324: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 324 of 328 Table of Figures ...
Страница 328: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 328 of 328 Notes ...
Страница 329: ......