![Baumuller b maXX 5000 Скачать руководство пользователя страница 318](http://html.mh-extra.com/html/baumuller/b-maxx-5000/b-maxx-5000_instruction-handbook-manual_2711361318.webp)
WARNING!
Function test requirements of the safety function to comply with the
Safety Integrity
Level SIL2
respectively with the
Performance level PLd, category 3
:
The safety function has to be tested (activated/deactivated) at least once a year.
The DC-link voltage must be measured in STO state once a year. The measured
value must be
60 V.
Description of the safety function STO
Instruction handbook
b maXX
5000
Document No.: 5.09021.16
Baumüller Nürnberg GmbH
318
C.7
No proof test is necessary during the expected device life cycle of 20 years.
CAUTION!
If the user calculates the safety application for the specified values with 20 years, the
device must be decommissioned after 20 years. This is the maximum life cycle time
of the device. The device must be decommissioned after this time. The device must
be properly disposed of.
It is not possible to perform a proof test.
NOTICE!
The proper condition of the controller’s fan must be checked before commissioning.
The maintenance and cleaning of the fan must be made at least once a year.
C.7.2 Reaction time STO
The reaction time period starting from the change of the input state to U
L
(see also
on page 316) to the disconnection of the DC link is maximum 5 ms.
CAUTION!
The existing capacitance of the decentralized drive solutions BM2500 connected to
the DC link is discharged in case of active STO function. The time period for this
discharge can be significantly greater than the reaction time, depending on the
number of connected decentralized drive solutions BM2500. The discharge of the DC
link is no part of the safety function.
Содержание b maXX 5000
Страница 101: ...Design and Operation Instruction handbook b maXX 5000 Document No 5 09021 16 101 of 328 4 ...
Страница 220: ...Fieldbus communication Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 220 of 328 8 4 ...
Страница 240: ...Error handling Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 240 of 328 10 4 ...
Страница 298: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 298 of 328 A ...
Страница 299: ...299 of 328 Operation Manual b maXX 5000 Document no 5 09021 16 APPENDIX B DECLARATION OF CONFORMITY ...
Страница 324: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 324 of 328 Table of Figures ...
Страница 328: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 328 of 328 Notes ...
Страница 329: ......