![Baumuller b maXX 5000 Скачать руководство пользователя страница 56](http://html.mh-extra.com/html/baumuller/b-maxx-5000/b-maxx-5000_instruction-handbook-manual_2711361056.webp)
Operating conditions
Instruction handbook
b maXX
5000
Document No.: 5.09021.16
Baumüller Nürnberg GmbH
56
3.3
3.3.6
Cooling
Cooling air temperature
1)
Min. 5 °C to max. 55 °C
(rated temperature: 40 °C),
refer to correction values temperature
Cooling air requirement
2)
Depends on the device, refer to
Coolant temperature
4)
Min. surrounding temperature up to max. 55 °C
(rated temperature: 40 °C),
refer to correction values temperature
Coolant flow
3)
Min. 4 l/min. to max. 15 l/min
Coolant pressure
3)
Max. 6 bar
Coolant hysteresis
Max. 5 K in static and dynamic operation
Water heating
(coolant in to coolant out)
3)
[K]
14
35
l/min
kW
------------
K
power loss kW
coolant flow [l/min]
-------------------------------------------------
Pressure drop
at the water cooling unit
3)
0.5 bar at 10 l/min
Surface temperature
Cold plate / mounting base
4) 5)
Min. surrounding temperature up to max. 55 °C
(rated temperature: 40 °C),
refer to correction values temperature
1)
Air temperature in the entire intake area of the device.
2)
The cooling air requirement corresponds to at least that of a freely-blowing device. Freely-blowing means that the air flow in and out are
unobstructed. Therefore, when installing the device in a control cabinet, it could be necessary to make use of additional fans in order
that the necessary cooling air requirement is covered. If the necessary cooling air requirement of the passive cooling unit is not provided
for, then the output power of the device must be reduced.
Figure 29:
Cooling air requirement
Содержание b maXX 5000
Страница 101: ...Design and Operation Instruction handbook b maXX 5000 Document No 5 09021 16 101 of 328 4 ...
Страница 220: ...Fieldbus communication Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 220 of 328 8 4 ...
Страница 240: ...Error handling Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 240 of 328 10 4 ...
Страница 298: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 298 of 328 A ...
Страница 299: ...299 of 328 Operation Manual b maXX 5000 Document no 5 09021 16 APPENDIX B DECLARATION OF CONFORMITY ...
Страница 324: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 324 of 328 Table of Figures ...
Страница 328: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 328 of 328 Notes ...
Страница 329: ......