Installation
Instruction handbook
b maXX
5000
Document No.: 5.09021.16
189
7
X6
Analog inputs/outputs
1
: Input 1 +
2
: Input 2 +
3
: GND
4
: Output 1 +
5
: Output 2 +
6
: Input 1 -
7
: Input 2 -
8
: Output 1 (GND)
9
: Output 2 (GND)
Only one encoder can be connected to each
encoder connection.
X7
Encoder 1
*)
Switchable:
HIPERFACE
®
Resolver
Firmware 1.04 and above:
Encoder with EnDat
®
2.1
Sine/square wave incremental encoder
Firmware 1.06 and above:
Encoder with SSI, EnDat
®
2.2
HIPERFACE DSL
®
Firmware 1.15 and above
Sine incremental encoder with commutation
X8
Encoder 2
*)
Switchable:
HIPERFACE
®
Resolver
Firmware 1.04 and above:
Encoder with EnDat
®
2.1
Sine/square wave incremental encoder
Firmware 1.06 and above:
Encoder with SSI, EnDat
®
2.2
HIPERFACE DSL
®
Firmware 1.15 and above
Sine incremental encoder with commutation
*)
Figure 89:
Connection of analog inputs/outputs and encoder BM53XX
Содержание b maXX 5000
Страница 101: ...Design and Operation Instruction handbook b maXX 5000 Document No 5 09021 16 101 of 328 4 ...
Страница 220: ...Fieldbus communication Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 220 of 328 8 4 ...
Страница 240: ...Error handling Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 240 of 328 10 4 ...
Страница 298: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 298 of 328 A ...
Страница 299: ...299 of 328 Operation Manual b maXX 5000 Document no 5 09021 16 APPENDIX B DECLARATION OF CONFORMITY ...
Страница 324: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 324 of 328 Table of Figures ...
Страница 328: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 328 of 328 Notes ...