Installation
Instruction handbook
b maXX
5000
Document No.: 5.09021.16
195
7
Sine or square
wave
encoder evalua-
tion
The encoders, which meet the following technical specifications, can be used:
Voltage supply
5 V
DC
controlled
Signal level
RS422 (TTL) for square wave incremental encoders
~1 Vss for sine incremental encoders
Current input
Max. 250 mA
D-sub-connector
26-pin
1
GND encoder supply
2
+5 V encoder supply
3
reserved *
4
RS422 A +
5
RS422 A -
6
RS422 B +
7
RS422 B -
8
RS422 0 +
9
RS422 0 -
10
reserved *
11
Sense GND
12
Sense V
CC
13
reserved *
14
reserved *
15
reserved *
16
reserved *
17
Tempe
18
Temperature -
19
reserved *
20
reserved *
21
reserved *
22
reserved *
21
reserved *
22
reserved *
23
reserved *
24
reserved *
25
reserved *
26
reserved *
* do not occupy
Содержание b maXX 5000
Страница 101: ...Design and Operation Instruction handbook b maXX 5000 Document No 5 09021 16 101 of 328 4 ...
Страница 220: ...Fieldbus communication Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 220 of 328 8 4 ...
Страница 240: ...Error handling Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 240 of 328 10 4 ...
Страница 298: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 298 of 328 A ...
Страница 299: ...299 of 328 Operation Manual b maXX 5000 Document no 5 09021 16 APPENDIX B DECLARATION OF CONFORMITY ...
Страница 324: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 324 of 328 Table of Figures ...
Страница 328: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 328 of 328 Notes ...
Страница 329: ......