Connection diagrams
Instruction handbook
b maXX
5000
Document No.: 5.09021.16
Baumüller Nürnberg GmbH
144
7.13
BM50XX-XX01
Normally closed contact expected on the inhibit input.
NOTICE:
Connection for
external brake
resistor, only.
Do not connect
an additional
capacitance.
External brake
resistor
Figure 65:
Connection diagram for the BM50XX-XX01 without safety function
NOTE!
The use of a power choke (L1) is mandatory for the function of the mains rectifier unit.
An operation without power choke is not allowed.
1C1, 1D1
Connections for the DC link, see
PE
Power supply PE-connection
1U1, 1V1,
1W1
Power supply connection, see
F1
Fuses (cable + device)
L1
Power choke
Z1
Line filter
K1
Main contactor (option)
X200
Connections for 24 V voltage supply; for additional information, see
157 (SELV/PELV).
X1
Control inputs and outputs, for additional information see
Electrical connections of the BM50XX-XX0X-... without safety function
X300
Signal bus
X101
Brake resistor
Содержание b maXX 5000
Страница 101: ...Design and Operation Instruction handbook b maXX 5000 Document No 5 09021 16 101 of 328 4 ...
Страница 220: ...Fieldbus communication Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 220 of 328 8 4 ...
Страница 240: ...Error handling Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 240 of 328 10 4 ...
Страница 298: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 298 of 328 A ...
Страница 299: ...299 of 328 Operation Manual b maXX 5000 Document no 5 09021 16 APPENDIX B DECLARATION OF CONFORMITY ...
Страница 324: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 324 of 328 Table of Figures ...
Страница 328: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 328 of 328 Notes ...
Страница 329: ......