LED display BM5030 with safety function
Instruction handbook
b maXX
5000
Document No.: 5.09021.16
Baumüller Nürnberg GmbH
306
C.4
C.4
LED display BM5030 with safety function
BM5030-XX2X-...
LED
H1
READY - Mains rectifier unit ready-to-operate:
green
:
Power supply and DC link voltage available, internally
OK
red
:
Power supply failure - automatically restart when power
supply returns.
blinking red:
Power supply failure longer than 10 s - restart after
Power supply return has to be acknowledged (X1:4).
Refer to
Error acknowledgment of BM50XX
LED
H2
PHASE FAILURE
red
:
Phase failure
LED
H3
OVERTEMPERATURE
red
:
Overtemperature
LED
H4
DC-LINK ERROR
red
:
DC link error:
U
DC link
overvoltage or
U
DC link
overcurrent or
Inhibit input active
LED
H5
LED
H6
STO POWER
green
:
U
DC
is available
orange
:
U
DC
is not ready
red
:
Error
STO STATUS
green
:
Ready-to-operate
orange
:
U
DC link
charging procedure,
red
:
STO error
Figure 127:
Display/operating elements BM5030-XX2X-...
Содержание b maXX 5000
Страница 101: ...Design and Operation Instruction handbook b maXX 5000 Document No 5 09021 16 101 of 328 4 ...
Страница 220: ...Fieldbus communication Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 220 of 328 8 4 ...
Страница 240: ...Error handling Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 240 of 328 10 4 ...
Страница 298: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 298 of 328 A ...
Страница 299: ...299 of 328 Operation Manual b maXX 5000 Document no 5 09021 16 APPENDIX B DECLARATION OF CONFORMITY ...
Страница 324: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 324 of 328 Table of Figures ...
Страница 328: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 328 of 328 Notes ...
Страница 329: ......