7.11.6 Option: STO function
Axis module 1: X1-1
(SELV/PELV)
Axis module 2: X1-2
(SELV/PELV)
Axis module 3: X1-3
(SELV/PELV)
Pin assignment
X1-1, X1-2, X1-3
Pin No.
Assignment
1
7
8
14
1
STO1 GND axis 1 of axis module 1 / 2 / 3
2
STO2 GND axis 1 of axis module 1 / 2 / 3
3
Not assigned
4
STO1 GND axis 2 of axis module 1 / 2 / 3, double axis modules only
5
STO2 GND axis 2 of axis module 1 / 2 / 3, double axis modules only
6
Not assigned
7
STO1 24V axis 2 of axis module 1 / 2 / 3, double axis modules only
8
STO1 24V axis 1 of axis module 1 / 2 / 3
9
STO2 24V axis 1 of axis module 1 / 2 / 3
10
Not assigned
11
Reserved, internal connected with pin 7,
STO1 24V axis 2 of axis module 1 / 2 / 3, double axis modules only
12
STO2 24V axis 2 of axis module 1 / 2 / 3, double axis modules only
13
Not assigned
14
Reserved, internal connected with pin 8,
STO1 24V axis 1 of axis module 1 / 2 / 3
Digital input:
Low
voltage: -0.3 … 5 V
High
Voltage: 20 … 30 V
Max. reaction time
Max. 30 ms
NOTE!
The used power supply must comply with the defined power supply interruption ac-
cording EN60204-1.
Содержание b maXX 5000 BM5800 Series
Страница 158: ...Recommissioning Instruction handbook b maXX 5800 Document No 5 16027 04 Baumüller Nürnberg GmbH 158 of 174 12 6 ...
Страница 164: ...Instruction handbook b maXX 5800 Document No 5 16027 04 Baumüller Nürnberg GmbH 164 of 174 ...
Страница 165: ...165 of 174 Operation Manual b maXX 5800 Document no 5 16027 04 APPENDIX B DECLARATION OF CONFORMITY ...
Страница 168: ...Operation Manual b maXX 5800 Document no 5 16027 04 Baumüller Nürnberg GmbH 168 of 174 ...
Страница 174: ...Instruction handbook b maXX 5800 Document No 5 16027 04 Baumüller Nürnberg GmbH 174 of 174 Notes ...
Страница 175: ......