4.4
4.4.2.3 Option: 7-segment display
Refer to parameter manual for detailed description of drive states and state transitions.
0: Low, 1: High
Display
State
drive manager
Meaning
0
NOT READY TO SWITCH ON
Drive message „Not ready for switching power on“
1
SWITCH-ON INHIBIT
Inhibit voltage, e.g. quick stop active
2
READY TO SWITCH ON
Drive shutdown
Control word: xxxx x110
Pulse enable = 0
Quick stop = 1 (low active)
3
SWITCHED ON
Control word: xxxx x111
Pulse enable = 1
Quick stop = 1
4
OPERATION ENABLED
Control word: xxxx 1111
Pulse enable = 1
Quick stop = 1
5
BETRIEB SPERREN AKTIV
6
OPERATION INHIBIT ACTIVE
Pulse enable = 0
7
QUICK STOP ACTIVE
Quick stop = 0 (low active)
E
ERROR RESPONSE ACTIVE
F
ERROR
Error message
Reset via control word 0xxx xxxx
or reset stored errors 0
➝
1
P
Parking axis
NOTE!
In addition the error No. is displayed.
Содержание b maXX 5000 BM5800 Series
Страница 158: ...Recommissioning Instruction handbook b maXX 5800 Document No 5 16027 04 Baumüller Nürnberg GmbH 158 of 174 12 6 ...
Страница 164: ...Instruction handbook b maXX 5800 Document No 5 16027 04 Baumüller Nürnberg GmbH 164 of 174 ...
Страница 165: ...165 of 174 Operation Manual b maXX 5800 Document no 5 16027 04 APPENDIX B DECLARATION OF CONFORMITY ...
Страница 168: ...Operation Manual b maXX 5800 Document no 5 16027 04 Baumüller Nürnberg GmbH 168 of 174 ...
Страница 174: ...Instruction handbook b maXX 5800 Document No 5 16027 04 Baumüller Nürnberg GmbH 174 of 174 Notes ...
Страница 175: ......