Cabling
Instruction handbook
b maXX
5800
Document No. 5.16027.04
Baumüller Nürnberg GmbH
148
11.1
11.1.6.3 Connecting cable for encoder with EnDat
®
or SSI
The connecting cable is available as accessory part from Baumüller Nürnberg GmbH.
Follow the instructions below if a self-made cable is to be used:
1
Utilize the following materials:
m
Cable: Li9YC3x2x0.25-Li9Y3x2x0,25-Li9Y C11Y 1x2x0.34GN. Two cable pairs are
not needed and also not connected.
m
High-density D-sub connector: 26-pin, male
m
Round connector: 17-pin, female (e.g. from Interconnectron)
2
Fully adjoin the cable shield with the housing of the round connector and with the
shielding of the D-sub connector.
Figure 50:
Connecting cable for encoder with EnDat
®
or SSI
NOTE
The connecting cable must be made according to the figure shown above!
If there is a different pin assignment, the cable is not functionally operable and could
lead to defects, both in the encoder module and the encoder!