Fieldbus communication
Instruction handbook
b maXX
5800
Document No. 5.16027.04
Baumüller Nürnberg GmbH
122
8.3
8.3.4
POWERLINK
®
.
Type code
b maXX 5800
with POWERLINK
®
:
BM58XX-XX-XXXXXX-XXXXXX-XXXXXX-XX
4
-
b maXX 5800
devices can communicate with a POWERLINK
®
Managing Node via the
fieldbus connection POWERLINK
®
.
X3
and
X4
on the front side of the device are the RJ45 connections for POWERLINK
®
.
Mounting and in-
stallation
.
The mounting/installation consists of the following steps:
1
De-energize the
b maXX 5800
device
2
Connect
b maXX 5800
with Ethernet-connection cables.
n
Please, observe an EMC-compatible laying of the Ethernet connection cables!
n
The following cables were released for use by Baumüller:
Ethernet-connection cable;
142.
Commissioning
.
The following preconditions must be fulfilled before commissioning:
1 b maXX 5800
with POWERLINK
®
is installed correctly.
n
Ethernet-connection cables are wired correctly.
2
The control cabinet is properly locked and all safety devices are operating.
3
The
b maXX 5800
device is ready-to-use.
Parameters
The parameter settings determine the behavior of the POWERLINK
®
Controlled Node in
operation. Parameters are set with the software ProDrive.
1
Start ProDrive
2
Click on „Project Tree“.
3
Communication settings with ProDrive
n
Project Tree: Configuration/Fieldbus Slave
(refer also Parameter manual
b maXX 5800
)
m
Set Synchronization to „On“
m
SYNC time = Fieldbus cycle time = POWERLINK
®
cycle time = 500 µs to 8 ms
This setting is not necessary if using the POWERLINK
®
profile and the POWER-
LINK
®
Managing Node sets a valid value in object 0x1006 „Communication cycle
period“.
Содержание b maXX 5000 BM5800 Series
Страница 158: ...Recommissioning Instruction handbook b maXX 5800 Document No 5 16027 04 Baumüller Nürnberg GmbH 158 of 174 12 6 ...
Страница 164: ...Instruction handbook b maXX 5800 Document No 5 16027 04 Baumüller Nürnberg GmbH 164 of 174 ...
Страница 165: ...165 of 174 Operation Manual b maXX 5800 Document no 5 16027 04 APPENDIX B DECLARATION OF CONFORMITY ...
Страница 168: ...Operation Manual b maXX 5800 Document no 5 16027 04 Baumüller Nürnberg GmbH 168 of 174 ...
Страница 174: ...Instruction handbook b maXX 5800 Document No 5 16027 04 Baumüller Nürnberg GmbH 174 of 174 Notes ...
Страница 175: ......