Accessories and spare parts
Instruction handbook
b maXX
5800
Document No. 5.16027.04
141
11
m
Motor cable with HIPERFACE DSL
®
36 A
Connect cable shield with the
housing of the connector.
Cable length
(according order)
Heat shrink tubing
Pin 1
Connect the cable shielding
via the strain relief clamp
of the connector housing.
400 mm
Data cable shielded
DSL- blue
DSL+
Pin 19 DSL-
Pin 20 DSL+
B+
B-
V
W
GN/GE
U
white
Figure 47:
Motor cable with HIPERFACE DSL
®
36 A
Cable: 4G6.0+(2x1.0)+(2x22AWG)
Shielding: copper wires, tinned.
Motor side:
Circular metal connector-pin speedtec
®
M40 9-pin
Outside shielding and inside shielding must be wired separately.
Device side:
Metal D-sub connector 45°, 26-pin with electronics, part No. 460219
Connect inside shielding with the connector housing.
Circular connector
speedtec
®
M40
Type of stranding
Unconnected
wires
Cross section of wire
U
U
6 mm² / black / U
V
V
6 mm² / black / V
W
W
6 mm² / black / W
GN/GE
6 mm² / green-yellow
+
B+
1,0 mm² / black
-
B-
1,0 mm² / black
H
DSL+
22 AWG / white
L
DSL-
22 AWG / blue
Housing
-
Outside shielding
Housing
-
Inside shielding
Содержание b maXX 5000 BM5800 Series
Страница 158: ...Recommissioning Instruction handbook b maXX 5800 Document No 5 16027 04 Baumüller Nürnberg GmbH 158 of 174 12 6 ...
Страница 164: ...Instruction handbook b maXX 5800 Document No 5 16027 04 Baumüller Nürnberg GmbH 164 of 174 ...
Страница 165: ...165 of 174 Operation Manual b maXX 5800 Document no 5 16027 04 APPENDIX B DECLARATION OF CONFORMITY ...
Страница 168: ...Operation Manual b maXX 5800 Document no 5 16027 04 Baumüller Nürnberg GmbH 168 of 174 ...
Страница 174: ...Instruction handbook b maXX 5800 Document No 5 16027 04 Baumüller Nürnberg GmbH 174 of 174 Notes ...
Страница 175: ......