Cabling
Instruction handbook
b maXX
5800
Document No. 5.16027.04
Baumüller Nürnberg GmbH
138
11.1
m
Motor cable with HIPERFACE DSL
®
20 A
Connect cable shield with the
housing of the connector.
Cable length
(according order)
Heat shrink tubing
Pin 1
1
3
A
D
4
Connect the cable shielding
via the strain relief clamp
of the connector housing.
400 mm
Data cable shielded
DSL- blue
DSL+ white
Pin 19 DSL-
Pin 20 DSL+
B+
B-
V
W
GN/GE
U
Figure 44:
Motor cable with HIPERFACE DSL
®
20 A
Cable: 4G2.5+(2x1.0)+(2x22AWG)
Shielding: copper wires, tinned.
Motor side:
Circular metal connector speedtec
®
M23 8-pin.
Connect outside shielding and inside shielding with the connector housing.
Device side:
Metal D-sub connector 45°, 26-pin with electronics, part No. 460219.
Connect inside shielding with the connector housing.
Circular connector
speedtec
®
M23
Type of stranding
Unconnected
wires
Cross section of wire
1
U
2,5 mm² / black / U
3
V
2,5 mm² / black / V
4
W
2,5 mm² / black / W
GN/GE
2,5 mm² / green-yellow
A
B+
1,0 mm² / black
B
B-
1,0 mm² / black
C
DSL+
22 AWG / white
D
DSL-
22 AWG / blue
Housing
-
Outside shielding
Housing
-
Inside shielding
Содержание b maXX 5000 BM5800 Series
Страница 158: ...Recommissioning Instruction handbook b maXX 5800 Document No 5 16027 04 Baumüller Nürnberg GmbH 158 of 174 12 6 ...
Страница 164: ...Instruction handbook b maXX 5800 Document No 5 16027 04 Baumüller Nürnberg GmbH 164 of 174 ...
Страница 165: ...165 of 174 Operation Manual b maXX 5800 Document no 5 16027 04 APPENDIX B DECLARATION OF CONFORMITY ...
Страница 168: ...Operation Manual b maXX 5800 Document no 5 16027 04 Baumüller Nürnberg GmbH 168 of 174 ...
Страница 174: ...Instruction handbook b maXX 5800 Document No 5 16027 04 Baumüller Nürnberg GmbH 174 of 174 Notes ...
Страница 175: ......