Connection diagrams
Instruction handbook
b maXX
5800
Document No. 5.16027.04
Baumüller Nürnberg GmbH
108
7.11
7.11.12Option: Analog outputs
X6
Analog outputs
Resolution
12 Bit
Output voltage
-10 V to +10 V
Output current max.
1 mA
Refreshing rate
62.5 µs
Short-circuit proof
Limited, max. 10 s
Outputs
4 analog outputs are provided:
Pin No.
Assignment
1
Analog output 3 +
2
Analog output 4 +
3
Ground
4
Analog output 1 +
5
Analog output 2 +
6
Analog output 3 -
7
Analog output 4 -
8
Analog output 1 -
9
Analog output 2 -
Pin assignment
X6