Design and Operation
Instruction handbook
b maXX
5800
Document No. 5.16027.04
49
4
4.2.3
Type code
The type code has the format:
BM58XX -XX-XXXXXX-XXXXXX-XXXXXX-XXX-XXXX-XXXX-EXX
The type code is explained in the following table.
BM5
8XX-XX-XXXXXX-XXXXXX-XXXXXX-XXX-XXXX-XXXX-EXX
Device generation
BM
5
8
XX-XX-XXXXXX-XXXXXX-XXXXXX-XXX-XXXX-XXXX-EXX
Device design
0: Mains rectifier
1: Active mains rectifier
3: Axis unit safety
5: Basic unit/power module safety
6: Basic unit/power module safety,
optimized for peak current
7: Basic unit/power module safety,
optimized for rated current, water-cooled
8: Multi-axis controller safety
BM58
XX
-XX-XXXXXX-XXXXXX-XXXXXX-XXX-XXXX-XXXX-EXX
Housing size
07: 175 mm width,
BM58XX-
X
X-XXXXXX-XXXXXX-XXXXXX-XXX-XXXX-XXXX-EXX
Type of cooling
S: Air-cooled with air supply and with air outlet in the
control cabinet
A: Air-cooled with air supply and with air outlet out-
side the control cabinet - through-hole device
BM58XX-X
X
-XXXXXX-XXXXXX-XXXXXX-XXX-XXXX-XXXX-EXX
Type of power supply system
G: Multi-axis controller,
mains inverter connected to Grounded delta
systems, IT systems, grounded TN or TT sys-
tems
Содержание b maXX 5000 BM5800 Series
Страница 158: ...Recommissioning Instruction handbook b maXX 5800 Document No 5 16027 04 Baumüller Nürnberg GmbH 158 of 174 12 6 ...
Страница 164: ...Instruction handbook b maXX 5800 Document No 5 16027 04 Baumüller Nürnberg GmbH 164 of 174 ...
Страница 165: ...165 of 174 Operation Manual b maXX 5800 Document no 5 16027 04 APPENDIX B DECLARATION OF CONFORMITY ...
Страница 168: ...Operation Manual b maXX 5800 Document no 5 16027 04 Baumüller Nürnberg GmbH 168 of 174 ...
Страница 174: ...Instruction handbook b maXX 5800 Document No 5 16027 04 Baumüller Nürnberg GmbH 174 of 174 Notes ...
Страница 175: ......