76
ScreenPRO-II Controller • User’s Guide
3. Hardware Installation
System Installation
12. Power Connection
a.
Connect an AC power cord to the
AC Power Connector
on the rear of
each ScreenPRO-II chassis, and then to AC outlets.
b.
Connect an AC power cord to the
AC Power Connector
on the rear of
the ScreenPRO-II Controller chassis, and then to an AC outlet.
c.
Per your system configuration, connect AC Power cords to MatrixPRO
routers and BlendPRO-II, and then to AC outlets.
d.
Connect AC Power cords (or AC adapters) to all peripheral equipment,
such as Ethernet Hubs and monitors.
Please note:
~
Connect each unit only to a properly rated supply circuit.
~
Reliable grounding of rack-mounted equipment should be maintained.
13. Tally Connection
— If you are using the optional
Tally board, connect tally “relay
closure” lines from the ScreenPRO-II Controller’s
Tally
connector to the desired
external devices (such as cameras). Eight tally circuits are provided. In
Appendix A, refer to the “
Tally Connector
” section on page 262 for pinout details
14. Power On
— turn on power to all units.
15. System ID
— required for use with the ScreenPRO-II Controller. On each
ScreenPRO-II chassis:
a.
Access the
Remote Control
Menu
by pressing {
REMOTE CONTROL
}
on the
Home Menu
. This menu enables you to set the ID of the
ScreenPRO-II chassis.
b.
Set the ScreenPRO-II chassis ID to a unique value that is not used by
another chassis. The system will not function if duplicate IDs are in use.
16. Display Calibration
— calibrate the ScreenPRO-II Controller’s Touch Screen
display using the
Display Settings Menu
. From the
Home Menu
, press
{
DISPLAY
}
>
{
LCD CAL
},
and following the prompts to calibrate the display.
If you are using BlendPRO-II, please review the “
Overview of Edge-Blending
Technology
” section on page 79.
pÅêÉÉåmolJff=dÉåäçÅâ=qÉêãáå~íáçå
On the rear of each ScreenPRO-II chassis, one recessed
Termination Switch
is provided
for genlock termination (adjacent to the
Genlock Loop
connector).
•
Terminated
— when the switch is pushed in, the connection is terminated (75
Ohms).
•
Un-terminated
— when the switch is out, the connection is un-terminated.
If a particular ScreenPRO-II chassis is the last device in a reference video chain, ensure
that the
Termination Switch
is pushed in. If a particular ScreenPRO-II chassis is in the
middle of a reference chain, ensure that the
Termination Switch
is out.
Note
The ScreenPRO-II Controller will detect duplicate IDs and
prompt the user to correct the problem. Only the first device
will connect to the console. Other devices with conflicting IDs
will be refused a connection.
Содержание ScreenPRO-II
Страница 1: ...r d p molJff Manual 26 0505000 00 Revision A...
Страница 14: ...14 ScreenPRO II Controller User s Guide Table of Contents...
Страница 52: ...52 ScreenPRO II Controller User s Guide 2 Hardware Orientation Front Panel Sections...
Страница 84: ...84 ScreenPRO II Controller User s Guide 3 Hardware Installation Overview of Edge Blending Technology...
Страница 214: ...214 ScreenPRO II Controller User s Guide 5 System Setup Backup to Flash Memory Card...
Страница 266: ...266 ScreenPRO II Controller User s Guide K p ScreenPRO II Input and Output Resolutions...