![Barco ScreenPRO-II Скачать руководство пользователя страница 275](http://html1.mh-extra.com/html/barco/screenpro-ii/screenpro-ii_user-manual_3894006275.webp)
ScreenPRO-II Controller • User’s Guide
275
`K==réÖê~ÇáåÖ=pçÑíï~êÉ
Ethernet Upgrade Method
8.
Click the
Connect
button. If the connection is successfully, the message
“
Connect via Ethernet successful
” appears in the Flash Loader’s
Status Bar
. If
you cannot connect, refer to the “
Troubleshooting Ethernet Communication
”
section on page 275.
9.
To upload files to the ScreenPRO-II Controller, click "
Open script file to read and
upload
."
10.
In the dialog, select "
Complete_Load.sld
" and click
Open
. The ScreenPRO-II
Controller menu should immediately display the "
System in LOADER MODE
"
message.
11.
It takes several minutes to load the flash memory. When complete, the Flash
Loader utility displays the “
Upload Complete
” message. Click
OK
to continue.
12.
Cycle power on the ScreenPRO-II Controller, and exit the Flash Loader utility.
13.
On ScreenPRO-II Controller, perform a factory reset. In Chapter 5, refer to the
“
Return to Factory Default
” section on page 189 for instructions.
14.
On the ScreenPRO-II Controller, verify that the new software has been loaded
correctly. Press {
HOME
} >
SYSTEM
> {
SW VER
} to display the
Software
Version Menu
.
qêçìÄäÉëÜççíáåÖ=bíÜÉêåÉí=`çããìåáÅ~íáçå
Use the following steps to determine the IP address of ScreenPRO-II Controller, and
establish proper communications:
1.
Turn on the ScreenPRO-II Controller. Press {
HOME
} >
SYSTEM
> {
NETWORK
SETUP
} to display the
Network Setup Menu
.
2.
Make a note of the IP address.
3.
Attempt to ping the ScreenPRO-II Controller as follows:
a.
Connect ScreenPRO-II Controller’s Ethernet port to a Hub or Switch.
b.
Connect the Ethernet Hub or Switch to your PC. A totally “local” network
is recommended, without IP connections to the outside world.
c.
Turn on the PC or laptop.
d.
Open a command prompt window on the PC. Click
Start > Programs >
Accessories > Command Prompt
.
e.
On the command prompt line, type:
ping 192.168.0.2
... followed by
Enter
.
f.
If the computer is able to successfully communicate with the
ScreenPRO-II Controller, you will see a series of “
replies
” from the
target IP address. Repeat the upgrade procedure as outlined in the
“
Ethernet Upgrade Method
” section on page 274.
Note
The default IP address is
192.168.0.2
.
Note
Use the unit’s actual IP address, as determined in step
2
above.
Содержание ScreenPRO-II
Страница 1: ...r d p molJff Manual 26 0505000 00 Revision A...
Страница 14: ...14 ScreenPRO II Controller User s Guide Table of Contents...
Страница 52: ...52 ScreenPRO II Controller User s Guide 2 Hardware Orientation Front Panel Sections...
Страница 84: ...84 ScreenPRO II Controller User s Guide 3 Hardware Installation Overview of Edge Blending Technology...
Страница 214: ...214 ScreenPRO II Controller User s Guide 5 System Setup Backup to Flash Memory Card...
Страница 266: ...266 ScreenPRO II Controller User s Guide K p ScreenPRO II Input and Output Resolutions...