3. Mechanical setup
Barco – OverView cDG67-DL – R5976624– installation manual – Revision 03 – August-2005
______________________________________________________________
3-14
PCL01
Install the multiple power strip B365010.
Since the illumination unit is located at the
right side, the power strip is best to be placed
on the right z profile.
This power strip includes 6xIEC 320 sockets.
Powerstrip
Powerstrip
Powerstrip
mains voltage:
220V
mains voltage:
110V
PCL02
For later cabling of the illumination unit, see
schematics:
The power strip includes 6xIEC 320 sockets and
is rated for a max. current of 10A.
This means:
In countries using 220V, up to six power cables
of OverView D could be plugged in (i. e. the
illumination units of one column can all be
connected into one power strip).
In countries using 110 V, only up to three
power cables of OverView D illumination units
can be plugged into one power strip. Therefore
for display walls higher than 3 rows, a second
power strip per column has to be installed.
Of course the two power strips may not be
connected in series!
Always take care that the max. rating of the
power strip is not exceeded!