2. Pre-Installation requirements
Barco – OverView cDG67-DL – R5976624– installation manual – Revision 03 – August-2005
________________________________________________________________
2-3
2.5
Access
The buildings have to be accessible during extended straight time, 6AM – 12PM, 7 days per week.
From the delivery point to the installation site, the doors and passages require a minimum width of 1500mm
and height of 2000mm for an installation.
In case the projection-room is located on the ground floor the room need to be accessible with any trolley.
In case the projection-room is located on a floor level an elevator is required.
The elevator needs a minimum entrance and cabin size of 1500 x 1800 x 1200mm (width x height x depth). The
support power must be 1000 kg minimum. The elevator must be available during the installation period.
2.6
Installation and room requirements.
Behind the wall a minimum distance is required of 750mm. For the use of a HOIST 1000mm is required. At the
left or right side of the wall a passage is required of 750mm.
For walls with a height more than 2500 mm, a scaffold or tower wagon will be required. This equipment must be
able to reach the top of the wall. In case no HOIST is ordered and wall is more than 2500 mm high, equipment
must be foreseen to load the projectors into the wall. This equipment must be able to lift up the projector in a
stable way. The support must be able to hold the complete projector in a flat plane. Minimum load of 80kg. Take
care of the available distance behind the wall! The provided equipment and auxiliaries must be in line with the
international safety regulations.
In case the display wall is integrated in a wall, the gap between screen and wall must be constructed as detailed
in the mechanical drawings (front, top, and side view). Typical 100mm before mounting of the trim.
The installation room must be sufficiently high. Sufficient space (recommended > 200mm) must be provided
above the display wall.
A system responsible must be available during the installation for practical arrangements and safety reasons.
Free telephone access needs to be available for local communication.
2.7
Footprint
This footprint can be used to help you set out the wall configuration the room where the wall will be installed.
The circles at the side of the screen front are the rotation points for curved structures.