The iVu device can be controlled or monitored over Industrial Ethernet using Ethernet/IP
™
, Modbus/TCP, PCCC, or
PROFINET
®
protocols. This document will help you to set up the iVu in the desired configuration and provide you with
information you will need to connect to the master device (PLC, HMI, etc.).
Connection
Main Menu > System > Communications > Industrial Ethernet > Connection
Use the Connection to enable Ethernet/IP, PROFINET, Modbus or or PCCC protocols on the Industrial Ethernet channel.
Select Disable to completely disable the Industrial Ethernet channel.
Map
Main Menu > System > Communications > Industrial Ethernet > Map
The Map setting (Default/Custom) affects only I/O Assembly 0×65 or MODBUS/PCCC registers 30001 to 30240 at offset
55-166.
Default Map
Main Menu > System > Communications > Industrial Ethernet > Map > Default
The default map automatically maps sensor data for each inspection and is recommended when the execution order of
sensor types is the same across inspections. When an inspection includes multiple sensors, the first five sensor results are
shown starting at offset 55. Each sensor result occupies 20 words.
Table 6: I/O Assembly Instance 101 (0×65): DEFAULT MAP
WORD #
WORD NAME
Data Type
0
Input Bits ACK Register (see
(p. 140))
16-bit integer
1
(p. 140))
16-bit integer
2-3
Error Code
32-bit integer
4-5
Inspection Number
32-bit integer
6-7
Iteration Count
32-bit integer
8-9
Pass Count
32-bit integer
10-11
Fail Count
32-bit integer
12-13
Missed Triggers
32-bit integer
14-15
Current Inspection Time
Float
16
Sensor Pass/Fail Coil
16-bit integer
17-29
reserved
16-bit integer
30-52
Inspection Name
2-Word 20-Unicode characters
53-54
Frame Number
32-bit integer
55
Sensor Type ID (Sensor 1)
16-bit integer
56-74
Sensor 1 Specific Data
16-bit integer
75
Sensor Type ID (Sensor 2)
16-bit integer
76-94
Sensor 2 Specific Data
16-bit integer
95
Sensor Type ID (Sensor 3)
16-bit integer
96-114
Sensor 3 Specific Data
16-bit integer
115
Sensor Type ID (Sensor 4)
16-bit integer
116-134
Sensor 4 Specific Data
16-bit integer
135
Sensor Type ID (Sensor 5)
16-bit integer
136-154
Sensor 5 Specific Data
16-bit integer
155-170
reserved
16-bit integer
iVu Plus TG and Color Gen2 Image Sensors