Sensor-Specific Data
Data Size
Average Saturation
16
‐
bit Integer
Average Intensity
16
‐
bit Integer
Standard Deviation Red
32-bit float
Standard Deviation Green
32-bit float
Standard Deviation Blue
32-bit float
Standard Deviation Hue
32-bit float
Standard Deviation Saturation
32-bit float
Standard Deviation Intensity
32-bit float
Note: Average Color Sensor data that does not apply to the selected color space has a result of 0. For
example, if the HSI color space is selected, the Red, Green, and Blue data will have a result of 0.
Table 43: Color Compare Sensor ID = 7
Sensor-Specific Data
Data Size
Color Difference
16
‐
bit Integer
Intensity Difference
16
‐
bit Integer
Table 44: Color Area Sensor ID = 8
Sensor-Specific Data
Data Size
Area Count
32
‐
bit Integer
Area Range Minimum
32
‐
bit Integer
Area Range Maximum
32
‐
bit Integer
iVu
Output Values (Modbus/TCP Input or Holding Registers)- Custom Map
The Custom Map option allows for more flexibility regarding iVu Output Values. The Custom Map option allows the user to
choose which pieces of Sensor Specific Data are given space in the register map.
Table 45: iVu Output Values (Modbus/TCP Input or Holding Registers): CUSTOM MAP
04: Read Input Registers or 03: Read Holding Registers
Input REG #
Holding REG #
WORD NAME
DATA TYPE
1
1001
Inputs 10001-16
16-bit Integer
2
1002
Inputs 10017-32
16-bit Integer
3-4
1003-4
Error Code
32-bit Integer
5-6
1005-6
Inspection Number
32-bit Integer
7-8
1007-8
Iteration Count
32-bit Integer
9-10
1009-10
Pass Count
32-bit Integer
11-12
1011-12
Fail Count
32-bit Integer
13-14
1013-14
Missed Triggers
32-bit Integer
15-16
1015-16
Current Inspection Time
Float