Numeric ID
Text ID
Description
20600
NO_MATCHES_FOUND
Attempt to obtain value when no matches were found.
20800
NO_MATCHES_FOUND
Attempt to obtain value when no sort patterns were found.
80000
REMOTE_DISPLAY_NOT_CONNECTED
Remote Display must be connected to obtain this value
80001
REMOTE_DISPLAY_NOT_SUPPORTED
This device does not have Remote Display capability
80100
COMMAND_MODE_EXPECTED
The Trigger Mode must be set to "Command" perform this
operation
80101
COMMAND_TIMED_OUT
The command timed out before finishing
80102
TRIGGER_REQUIRED
Access to the specified data requires a triggered inspection
80150
COMMAND_TIMED_OUT
The command timed out before finishing
80200
SYSTEM_ERROR_NOT_ACTIVE
The System Error must be active to execute this command
80300
TEACH_SENSOR_TYPE_INVALID
Teach requires Match sensor.
80350
MULTIPLE_INSPECTIONS_DISABLED
Requires multiple inspections to be enabled
80351
MULTIPLE_INSPECTIONS_EMPTY
No inspections are available in multiple inspection mode.
80400
PRODUCT_CHANGE_WHEN_NOT_READY
Sensor must be in the READY state to perform a product change.
80401
PRODUCT_CHANGE_INVALID_INSPECTION
Attempt to product change to an unknown or invalid inspection.
80402
PRODUCT_CHANGE_TIMEOUT
The Product Change operation timed out.
80403
PRODUCT_CHANGE_TO_SAME_INSPECTION
Attempt to product change to the same inspection.
80404
SENSOR_NAME_NOT_FOUND
Attempt to use a command without a sensor name in a multi-
sensor inspection
Examples of Operation
The following examples show how to utilize the iVu Command Channel via the Industrial Ethernet connection.
Clear System Error
1. Write the number
81
as a 16-bit integer into the Command ID register.
2. Toggle the Command bit from 0 to 1 (bit 15 in the Input Bits/Input Coil Bits register).
3. Wait for the Command ACK flag to go from 0 to 1 (bit 15 in the Input Bits ACK/Input Coil Bits ACK register).
4. Verify that the Execution Error flag is not set (that is, the value should be 0). This is bit 15 in the Output Bits/Status
Coil Bits register. If the value is 1, read the Error Code register for more information.
5. Task Complete. Toggle the Command bit back to 0 (bit 15 in the Input Bits/Input Coil Bits register).
Get/Set Trigger Mode
Get the current Trigger Mode from the iVu.
1. Write the number
10001
as a 16-bit integer into the Command ID register.
2. Toggle the Command bit from 0 to 1 (bit 15 in the Input Bits/Input Coil Bits register).
3. Wait for the Command ACK flag to go from 0 to 1 (bit 15 in the Input Bits ACK/Input Coil Bits ACK register).
4. Verify that the Execution Error flag is not set (that is, the value should be 0). This is bit 15 in the Output Bits/Status
Coil Bits register. If the value is 1, read the Error Code register for more information.
5. Task Complete. Toggle the Command bit back to 0 (bit 15 in the Input Bits/Input Coil Bits register). Read the current
Trigger Mode value in the Command Response Int16 register.
iVu model
Trigger Mode
Int16 value
TG/Color/Color, BCR
External
1
TG/Color
Internal
2
TG/Color
Free Run
3
iVu Plus TG and Color Gen2 Image Sensors