Command
Command ID
Description
Data Type
Do
Set
Get
Trigger
Trigger Mode
1
10001 The iVu triggering mode. This value must match the
modes supported by the iVu.
Int16
Product Change
Product Change By
Name
21
This command forces the iVu to switch to the specified
inspection. The iVu does not transmit a response until
the iVu has completed the action. Inspection results
immediately after a product change are invalid until a
new trigger is received.
Byte Array
Imager
Gain
51
10051 The iVu value used to electronically brighten all image
pixels.
Int32
Exposure
52
10052 The iVu value used to control the amount of time the
imager is allowed to gather light for the image.
Int32
Status
Clear System Error
81
This command clears the system error LED and resets
the internal system error flag to false.
N/A
System
Reboot Sensor
101
This command restarts the iVu. If the iVu configuration
data is currently being saved, this command is blocked
until the save operation completes.
N/A
Save Configuration
102
This command saves all modified inspection and
configuration parameters. This command blocks all other
commands until all values have been persisted.
N/A
Info
Sensor Name
10151 User-assigned device name.
Byte Array
Model Number
10152 Device model number.
Byte Array
Serial Number
10153 Device serial number.
Byte Array
Firmware Version
10154 Device firmware (software) version.
Byte Array
Hour Counter
10155 The total number of hours the device has been
energized.
Byte Array
History
Clear History
301
This command clears all history fields for the active
inspection. History values include pass count, fail count,
execution times and sensor-specific history values.
N/A
Inspection
Inspection Name
10501 The name of the active inspection.
Byte Array
Trigger Mode
1000
Description
External
1
Inspections are initiated via the electrical trigger wire.
Internal
2
Inspections run continuously at the specified period (electrical trigger inputs are
ignored).
Free Run
3
Inspections run continuously (electrical trigger inputs are ignored).
Industrial Ethernet
10
Inspections are only trigged by Industrial Ethernet coils and commands.
Command
20
Inspections are only trigged by the Command Channel trigger commands.
iVu Plus TG and Color Gen2 Image Sensors
www.bannerengineering.com - Tel: + 1 888 373 6767
215