Error Code
Description
Recommended Solution
10054
The Connection to the sensor was
lost while receiving data.
• Verify the sensor is energized
• Verify the sensor communication cable is connected
• Verify all inline network equipment is energized, properly
configured and connected
• Verify all required network equipment cables are connected
• Verify the network adaptor is properly configured
• Verify the sensor IP address is valid
• Verify there are no other devices using the same IP address
• Verify the sensor subnet is valid
• Verify the sensor can be successfully pinged
• Verify the network firewall settings support connection to the
sensor
10055
The Connection to the sensor was
lost due to network keep alive
expiration.
• Verify the network adaptor link speed and duplex settings
• Verify the is sensor not stalled, or in shutdown mode
10070
The Connection to sensor was lost
due to a receive state machine
error.
• Verify the is sensor not stalled, or in shutdown mode
• Verify the sensor is supported by this version
10071
The Connection to sensor was lost
due to a receive state machine
error.
• Verify the is sensor not stalled, or in shutdown mode
• Verify the sensor is supported by this version
10080
The Connection to sensor was lost.
• Verify the sensor is energized
• Verify the sensor communication cable is connected
• Verify all inline network equipment is energized, properly
configured and connected
• Verify all required network equipment cables are connected
• Verify the network adaptor is properly configured
• Verify the sensor IP address is valid
• Verify there are no other devices using the same IP address
• Verify the sensor subnet is valid
• Verify the sensor can be successfully pinged
• Verify the network firewall settings support connection to the
sensor
10085
A connection to the sensor could
not be established. One or more
required channels failed to connect.
• Verify the sensor is energized
• Verify the sensor communication cable is connected
• Verify all inline network equipment is energized, properly
configured and connected
• Verify all required network equipment cables are connected
• Verify the network adaptor is properly configured
• Verify the sensor IP address is valid
• Verify there are no other devices using the same IP address
• Verify the sensor subnet is valid
• Verify the sensor can be successfully pinged
• Verify the network firewall settings support connection to the
sensor
10086
The connection to the sensor was
lost while receiving data.
• Verify the sensor is energized
• Verify the sensor communication cable is connected
• Verify all inline network equipment is energized, properly
configured and connected
• Verify all required network equipment cables are connected
• Verify the network adaptor is properly configured
• Verify the sensor IP address is valid
• Verify there are no other devices using the same IP address
• Verify the sensor subnet is valid
• Verify the sensor can be successfully pinged
• Verify the network firewall settings support connection to the
sensor