Error Codes
The iVu device provides error codes in cases when commands failed to execute successfully. If such an error occurs, the
Execution Error flag is set in the Output Bits/Status Register. When this bit is set, read the Error Code register to know the
reason for the failure. The following table lists the error codes:
Numeric ID
Text ID
Description
0
SUCCESS
Command processed successfully.
500
IE_TRIGGER_MODE_EXPECTED
The Trigger Mode must be set to Industrial Ethernet to perform this
operation.
510
IE_COMMAND_NOT_FOUND
The numeric Command ID specified was not found.
520
IE_COIL_ACTION_FAILED
The coil action resulted in a failure.
521
IE_COIL_ALREADY_BUSY
The coil was asserted before the previous execution completed.
522
IE_COIL_NOT_FINISHED
The coil was de-asserted prior to the execution completing.
523
IE_COIL_ANOTHER_ACTION_PENDING
The coil was asserted prior to another coil execution completing.
524
IE_COIL_MULTIPLES_DETECTED
Multiple coils were asserted simultaneously.
525
IE_COIL_ACK_INHIBITED
The coil action's output ACK was inhibited because the input coil
was no longer set.
10000
EMPTY_FRAME_RECEIVED
Indicates that the request was empty. The command channel
requires a command, any arguments, and an end-of-frame
delimiter.
10001
COMMAND_NOT_RECOGNIZED
The command specified is not recognized
10100
GROUP_MISSING
A Group ID must be specified immediately after the command
10101
GROUP_NOT_FOUND
The specified Group ID is invalid / unknown
10102
GROUP_ITEM_MISSING
A Group Item ID must be specified immediately after the Group ID
10103
GROUP_ITEM_NOT_FOUND
The specified Group Item ID is invalid / unknown
10152
NOT_READABLE
Attempt to get a value that is not readable
10153
NOT_WRITEABLE
Attempt to set a value that is not writeable
10250
NOT_A_METHOD
Method ID specified is not a method
10251
WRONG_ARGUMENT_COUNT
Total method arguments specified do not match method
10252
COMMAND_NOT_FINISHED
Attempt to issue command when a previous command has not
finished
10300
INVALID_ARGUMENT_TYPE
Item ID specified must be an item (not a group or method)
10301
DATA_VALUE_MISSING
Command missing item's data value
10340
MINIMUM_VALUE_EXCEEDED
New item value is below the minimum
10341
MAXIMUM_VALUE_EXCEEDED
New items value is above the maximum
10350
ARGUMENTS_DETECTED
Get command received with unneeded arguments
10351
INVALID_ARGUMENT_TYPE
Item ID specified must be an item (not a group or method)
10500
DATA_SET_EMPTY
Data export operation returned no results.
10900
SENSOR_NOT_READY
Command specified requires iVu to be in the READY state.
10920
SENSOR_TYPE_NOT_ACTIVE
Command specified belongs to a different sensor type.
10950
DEVICE_TYPE_INVALID
Command not supported on this device type.
15000
VALUE_INVALID
Text value is invalid / unknown
15050
VALUE_INVALID
Text value is invalid - expecting True or False
15100
STRING_TOO_LONG
String value specified exceeds maximum allowable length
20200
NO_AREAS_FOUND
Attempt to obtain value when no areas were found.
iVu Plus TG and Color Gen2 Image Sensors
216
www.bannerengineering.com - Tel: + 1 888 373 6767