Examples
>>
get info companyname
\x0D\x0A
<<
OK\x0D\x0A
<<
"Banner Engineering Corp."\x0D\x0A
>>
get info bootnumber
\x0D\x0A
<<
OK\x0D\x0A
<<
42\x0D\x0A
>>
get info uptimer
\x0D\x0A
<<
OK\x0D\x0A
<<
4:42:42:324\x0D\x0A
System Command Group
Command
Group
Item
Description
Do
System
Reboot
Reboots the device. Pre-empts other commands except Save.
Do
System
Save
Saves inspection and configuration parameters. Blocks until finished.
Should be used sparingly.
Get
Ethernet
IPAddress
Get the current active IP address of the device as a string.
Get
Ethernet
SubnetMask
Get the current active subnet mask of the device as a string.
Get
Ethernet
Gateway
Get the current active Gateway address of the device as a string.
Set
Ethernet
IPAddress
Set the IP address of the device. A valid IP address must be supplied as
a string (for example: 192.168.0.1). A Reboot command from the
command channel must follow to make the new IP address effective.
You may also set new Subnet Mask and Gateway address as required
before a Reboot command is sent to the device.
Set
Ethernet
SubnetMask
Set a new subnet mask. A Reboot command is required to be sent from
the command channel to make the new mask effective.
Set
Ethernet
Gateway
Set a new Gateway IP address. A Reboot command is required to be
sent from the command channel to make the new address effective.
Examples
>>
Do System Reboot
\x0D\x0A
<<
(No response received)
>>
Get Ethernet IP Address
\x0D\x0A
<<
OK\x0D\x0A
<<
"192.168.0.115"\x0D\x0A
>>
Set Ethernet IPAddress
192.168.0.114\x0D\x0A
<<
OK\x0D\x0A
Status Command Group
Command
Group
Item
Description
Get
Status
Ready
Flag indicating whether the system is ready to trigger (true) or busy
(false).
Get
Status
SystemError
Flag indicating whether a system error is active (true) or cleared (false).
Do
Status
ClearSystemError
Clears the system error LED and sets the internal flag to false.
iVu Plus TG and Color Gen2 Image Sensors
114
www.bannerengineering.com - Tel: + 1 888 373 6767