Verify :
Ready = 1
TriggerACK = 0
Ready
Trigger
TriggerACK = ‘1’
Read Results
Set
Trigger = 0
RPI 0 1
X X +Y X +Y +Z
TriggerACK
Set
Trigger = 1
Verify :
Ready = 1
TriggerACK = 0
Trigger
Figure 273. Trigger Timing Diagram
15.9 Command Channel Command Status Register
The command status register will confirm receipt of a command by reflecting the exact command ID received, regardless of
whether the command was valid or not.
15.10 Diagnostic Guide
iVu devices provide several methods to help diagnose communication issues when using Ethernet communications.
15.10.1 Ethernet Diagnostics
To verify Ethernet connectivity, follow these steps:
1. Verify that all of the cables are connected and properly seated.
2. Examine the Ethernet I/O LED located on the top of the iVu, between the Pass/Fail and System Status LEDs. The
light should be either on or blinking.
3. Go to System > Logs > System Log.
4. Verify that the log entry indicates that the Ethernet link is up: