AUTO Mode (Autonomous)
MPORTANT
I
This function allows unauthorized dispenses. The dispense information will not be associated to any mechanic or
operator.
• The total dispensed quantity will be stored under the general work order number (999999) .
• The AUTO sign at the display’s lower left corner indicates the manual mode .
Enter the AUTO Mode
To enter the AUTO Mode:
1 . Press and hold the
TOTAL
button .
2 . Press the following buttons one after the other:
10
,
1
,
0.1
,
AUTO
.
OTEE:
N
You can use this same button sequence to return to RF mode .
The solenoid will now unlock and the meter may be used as a normal preselection meter .
3 . Press the
AUTO
button to enter the preselection .
Reset to Standard Mode
To return the meter to the standard preselection mode, press the
RESET
button and start a communication with the assigned
“Network Connect (CON) Menu” on page 24
“RF Mode (Standard Pre-Selection Mode)” on page 29
.
If the communication was successful (no “F02” error code) the meter will lockout and fall back in the preselection mode . The
total quantity, which has been dispensed during the AUTO mode, will be automatically transmitted to the Master Keypad . It
will be assigned to
Misc. WO-Number
(default 999999), with the user named as “???” . The dispense result will be marked with
the
Status 16
for manual dispense .
Electrical Override
In case of an emergency or to interrupt a batch, the meter is equipped with an electrical override . This option automatically
closes the valve in the meter, stopping the flow immediately . The display will begin to flash because the meter does not sense
any flow . Batching can be continued after an override, even if the meter is in the middle of a programmed batch and the
display continues to flash .
1 . Press the red
SHUTOFF
button to activate the electrical override . This button can only be used when the valve is open .
2 . Press the
RESET
button to cue up the next batch and stop the display from flashing .
EPM-3 Rf Meter
Page 30
December 2014
FMS-UM-01200-EN-01