RF Mode (Standard Pre-Selection Mode)
Work Order Validation via the Dispense Keypad
0.00
L
7.2
Dispensed
Quantity
RF COM
Batch Size
When the battery pack is attached to the meter, the meter will
automatically enter the RF mode . The trigger is in a locked-out
position and no oil can be dispensed until a dispense order is
received by the meter .
1 . Press the
RESET
button on the meter to enable it to receive a dispense order provided by the Dispense Keypad . The
trigger will unlock .
2 . Pull the trigger to begin the dispensing of fluid . The valve will automatically lock in place, even though the trigger will fall
back to the closed position . The flow will automatically shut off when the programmed amount has been dispensed .
3 . To top off, pull the trigger to dispense fluid and release when the desired amount has been reached .
4 . Press the
RESET
button when finished . The total quantity will be transmitted to the keypad and the meter will return to a
locked-out position . The meter is now ready to receive the next dispense order from the keypad .
10 sec
02
Result stored in
Dispense Keypad
Preselection: Pull the trigger until it
latches and RELEASE the trigger.
No preselection (0 liter): Pull and HOLD
the trigger. The trigger won´t latch.
Press the
RESET button
Press the
RESET button
The red button will STOP
a dispense at any time.
Order stored in
Dispense Keypad
10 sec
02
CLACK
02