Configuration (CNF) Menu
Select
CNF MET REP 190
The
CNF
menu is used to set the system’s operation modes and
archiving methods .
System Reset
Resets the system parameters to the original factory settings .
Mileage Type
Defines the unit for the
Free Alphanumeric
field (Defined in Global Keypad Settings)
Top Off Timer
Specifies the amount of time, how long user can make additional dispenses . Is the time allowed after a dispense is completed
before the meter will automatically lockout and send the dispense results back . (Defined in Global Keypad Setting)
Internal Printer
Enables the internal ticket printer . (Defined in Global Keypad Settings)
External Printer
Enables the external report printer port . (Defined in Global Keypad Settings)
Barcode Scanner
This menu will define the external Printer port as a Barcode Reader Port (RS232), if the
External Printer
is enabled the
Barcode Scanner
menu will disappear .
Barcode Scanner
YES / NO
Select
YES
to enable the Barcode Scanner .
Scanner Lock
OFF PIN ALL
OFF
Data can be entered with Keypad & Barcode Scanner
PIN
PIN has to entered by Barcode Scanner
All
All data has to be entered with Barcode Scanner
PIN Encoded
YES / NO
When PIN or All is selected you can choose an additional prefix
character . The prefix character will not be displayed and cannot be
entered on the keypad .
Encode Prefix #
Choose the desired prefix, available characters are:
# $ % &´ ( ) * +, - Space / : ; < = > ? @ [ ] ^ ` { | } ! ” #
Display Timeout
100_
Defines the time, how long the scanned information will be shown on
the display in units of 1/10 second . For example, 100 = 1 second .
We recommend the following barcode scanners:
• Wall mounted: Datalogic Magellan 1000i
• Handheld: Datalogic Gryphon 4100
The scanner has to be programmed according to our specification . Null modem adapter has to be used between the keypad
serial port and the barcode scanner .