INJECTOR CALIBRATOR CD3
APPENDIX
Instructions 67-9319
Bacharach, Inc.
Page A-1
A1.0 APPENDIX A:
CALIBRATOR AUDIT KIT
A1.1 DESCRIPTION
The Calibrator Audit Kit is required for checking the critical parameters of the CD3 Calibrator in the field.
This allows the user to periodically insure his unit is set to original factory specifications. This kit is
calibrated at the factory using instrumentation whose accuracy is traceable to NIST (National Institute of
Science and Technology). Bacharach offers recalibration service.
A detailed set of instructions is included which shows the step by step audit procedure. All components are
housed in a convenient carrying case.
A1.2 KIT COMPONENTS
Dead Weight Tester
- Used to measure and adjust injector inlet pressure.
Test Gage Set
- Consisting of a precision 0 - 600 psi gage and shutoff valve, it is used to check gear pump
pressure and test discharge head performance.
Viscor Cup
- Used to check the viscosity of the calibration fluid. Each cup is serialized and calibrated by
the calibration fluid manufacturer.
Dummy Injector Assembly
- Simulates the injector for setting the exact inlet pressure using the dead
weight tester. lt is also used to check the discharge head performance.
Digital Indicator
- Indicates the clamping force in lbs. or temperature in °F, depending on the component
connected, temperature transducer or load cell.
Temperature Transducer Assembly
- Consists of an electronic sensor built into a fitting to provide
accurate fuel temperature measurement near the injector inlet.
Load Cell Assembly
- Consists of a load sensing device with an electrical output. Includeds adapters that
enable measurement of body to seat and plunger to body clamping forces.
A1.3 ORDERING INFORMATION
Part No.
Description
67-7707
Calibrator Audit Kit.
77-0452
Gear Pump Relief Valve Kit (Required for Calibrators manufactured before November,
1984).
Содержание 67-7622
Страница 26: ...Page 2 8 Bacharach Inc Instructions 67 9319 INSTALLATION INJECTOR CALIBRATOR CD3 NOTES ...
Страница 54: ...Page 3 28 Bacharach Inc Instructions 67 9319 OPERATION INJECTOR CALIBRATOR CD3 NOTES ...
Страница 68: ...Page 4 14 Bacharach Inc Instructions 67 9319 MAINTENANCE AND TROUBLESHOOTING INJECTOR CALIBRATOR CD3 NOTES ...
Страница 96: ...Page A 2 Bacharach Inc Instructions 67 9319 APPENDIX INJECTOR CALIBRATOR CD3 NOTES ...