![Bacharach 67-7622 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/bacharach/67-7622/67-7622_installation-and-operation-instruction_464773006.webp)
TECHNICAL DATA AND FEATURES (Continued)
•
Indicator Lights:
- Power (red) - Heat/Cool (amber) - Clamping (amber).
•
Accessibility: Two front and one upper left hand side hinged doors. All other panels have quick
turn fasteners for easy removal.
•
Dimensions: 50"W (1.27m) x 30"D (.76m) x 56" H (1.42m)
•
Weight (Dry): 1150 lbs. (521 kg)
•
Utilities Required:
- Electrical:
ELECTRICAL OPTIONS
Part #
Voltage
Phase
Freq.
3 HP Motor
5 HP Motor
Amps
Amps
67-7622
230 VAC
3
60 Hz
24
33
67-7623
460 VAC
3
60 Hz
12
17
67-7624
208 VAC
3
60 Hz
26
38
67-7625
220 VAC
3
50 Hz
25
35
67-7626
380 VAC
3
50 Hz
15
20
67-7627
440 VAC
3
50 Hz
13
18
- Air Pressure: 80-120 psi (2 CFM).
- Water: Cold tap, approximately 1.2 GPM (4.5 liter/min).
•
Accessories:
- Accessories are available for mounting and testing of all Cummins
injectors (mechanical) and injectors (mechanical) manufactured by
Diesel Technology Corporation for engine models 53, 71, 92, 92 marine,
149, and 8.2L. These accessories must be ordered separately.
- Provision for hanging all accessories on pegboard inside lower doors.
iv
Bacharach, Inc.
Instruction 67-9319
Содержание 67-7622
Страница 26: ...Page 2 8 Bacharach Inc Instructions 67 9319 INSTALLATION INJECTOR CALIBRATOR CD3 NOTES ...
Страница 54: ...Page 3 28 Bacharach Inc Instructions 67 9319 OPERATION INJECTOR CALIBRATOR CD3 NOTES ...
Страница 68: ...Page 4 14 Bacharach Inc Instructions 67 9319 MAINTENANCE AND TROUBLESHOOTING INJECTOR CALIBRATOR CD3 NOTES ...
Страница 96: ...Page A 2 Bacharach Inc Instructions 67 9319 APPENDIX INJECTOR CALIBRATOR CD3 NOTES ...