![Bacharach 67-7622 Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/bacharach/67-7622/67-7622_installation-and-operation-instruction_464773036.webp)
Page 3-10
Bacharach, Inc.
Instructions 67-9319
OPERATION
INJECTOR CALIBRATOR CD3
16. Release the HOLD TO OPERATE button
first
and
then
the CLAMP/UNCLAMP lever. The
lever will return to the center position.
For clamping to occur correctly, you must follow
this sequence.
The gauge reading will decrease from the green
segment of the dial to a lower reading (red seg-
ment) immediately after the CLAMP/UNCLAMP
valve lever is returned to the center position.
3.1.6.4 Connecting Fuel Arm
NOTE:
When first using the fuel arm,
make sure the O-ring is in place at the end
of the fuel arm. If the O-ring must be
replaced, see Troubleshooting Guide in
Section 4.
NOTE:
Some early style PTB and PTC
injectors may have to be reworked to
provide for the button head inlet orifice.
Unless reworked, they cannot be tested
with these accessories.
17. Make sure that the inlet fuel connector (round
knurled knob) is tightly secured to the fuel arm
assembly.
18. Swing the fuel arm into place over the injector.
19. Lower the connector tube over the inlet orifice
by moving the toggle clamp fully forward
(toward you) so it locks.
20. Adjust the fuel arm positioning as required to
obtain a leak free connection.
CAUTION:
To prevent being sprayed with calibration
fluid, make sure the fuel arm rests
vertically against the inlet orifice (with the
O-ring seal in place) and is not being
pulled sideways by the inlet hose.
The injector is now ready for testing (Section 3.1.8).
Figure 3-22. Injector Clamped
17
Inlet Fuel Connector
18
Fuel Arm
19
Inlet Orifice
Содержание 67-7622
Страница 26: ...Page 2 8 Bacharach Inc Instructions 67 9319 INSTALLATION INJECTOR CALIBRATOR CD3 NOTES ...
Страница 54: ...Page 3 28 Bacharach Inc Instructions 67 9319 OPERATION INJECTOR CALIBRATOR CD3 NOTES ...
Страница 68: ...Page 4 14 Bacharach Inc Instructions 67 9319 MAINTENANCE AND TROUBLESHOOTING INJECTOR CALIBRATOR CD3 NOTES ...
Страница 96: ...Page A 2 Bacharach Inc Instructions 67 9319 APPENDIX INJECTOR CALIBRATOR CD3 NOTES ...