Chapter 7: CCM AMP
85
e.
In the Time-Out fields, enter the number of seconds to wait for a reply from the RADIUS
servers, in the range 1-60.
f.
In the Retry Count fields, enter the number of attempts that will be made to authenticate a
user after a time-out on the RADIUS servers, in the range 1-10.
7. Click
Apply
to save any changes without exiting the AMP.
-or-
Click
OK
to save any changes and exit the AMP.
-or-
Click
Cancel
to exit the AMP without saving any changes.
Configuring Global Session Settings
The Global - Sessions subcategory specifies:
•
How history buffer data is handled at the start and end of the Telnet session. You may have the
data sent to the virtual terminal window automatically when a Telnet session is established
(Auto) or have it held until it is explicitly requested (Hold). You may also retain the history
buffer content when the Telnet session ends (Keep) or discard it (Clear).
•
Whether the appliance will automatically close an inactive Telnet session. When enabled, the
Telnet session is closed when the CCM appliance does not receive any data within a specified
number of minutes.
•
Whether the appliance will allow plain text sessions.
•
SSH settings, including the ability to enable and disable SSH, specify or modify an SSH
authentication mode, create an SSH key and display the current SSH fingerprints.
Either plain text sessions or SSH (or both) must be enabled in order to launch Serial Console
Viewer Telnet sessions. Failure to have either or both enabled will result in an invalid
configuration. Plain text sessions are enabled by default.
To specify history buffer control:
1. Click the
Settings
tab in the CCM AMP.
2. Select the
Global - Sessions
subcategory.
3. In the History Buffer Control area, select
Auto
or
Hold
for the Session Start action. Select
Keep
or
Clear
for the Session End action.
4. Click
Apply
to save any changes without exiting the AMP.
-or-
Click
OK
to save any changes and exit the AMP.
-or-
Click
Cancel
to exit the AMP without saving any changes.
To specify session time-out settings:
1. Click the
Settings
tab in the CCM AMP.
2. Select the
Global - Sessions
subcategory.
Содержание AV Works
Страница 4: ......
Страница 10: ...viii AVWorks Installer User Guide...
Страница 12: ...x AVWorks Installer User Guide...
Страница 18: ...6 AVWorks Installer User Guide...
Страница 48: ...36 AVWorks Installer User Guide...
Страница 92: ...80 AVWorks Installer User Guide...
Страница 134: ...122 AVWorks Installer User Guide...
Страница 142: ...130 AVWorks Installer User Guide...