7.7 A
PPLICATOR
I
NTERFACE
(
OPTION
)
ALS
20X
256
24 V supply voltage outputs:
– Sensors: I
max
= 10 mA
– Fan (pin 28): I
max
= 1 A
– Pin 43: I
max
= 100 mA
Start
– Input
– I
in
< 6 mA
– Signal is generated by the product
sensor
– Starts dispensing
– Dispenser reaction time is higher
than after a start signal at the M12
start input (application for direct
dispensing is not advisable)
– CAUTION! - Initially, this signal in-
put is
deactivated
. The standard
Start signal input (M12 connector)
is activated. This setting can be
changed with
SIGNAL INTERFACE
>ACTIVE INPUTS > Start signal
Home
– Input
– I
in
< 6 mA
– Active, if the applicator has
reached the home position (appli-
cation is finished)
Touch Down
– Input
– I
in
< 6 mA
– Use with sensor-controlled appli-
cators (e. g. LTP)
– Active, if the applicator touches
the product
Repeat
– Input
– I
in
< 6 mA
– Same function as start signal
Feed
– Input
– I
in
< 6 mA
– Feeding of the label material as
long as the signal is active; at least
one label is dispensed
Signal name
Function
[186] Position and pin assignment of the internal applicator
connection (CN 609).
Start K 2
+24 V 4
Reserved 6
GND 8
Reserved 10
1 Start A
3 GND
5 Reserved
7 Key
9 Reserved
CN 402