9.3 O
PENING
THE
CASING
ALS
20X
256
9.3.2 For machines held in place by side
plate or base plate
Prerequisites:
– The machine is secured via a flange attached to the
side plate or base plate [209].
– The machine is de-energised.
Tools:
– Hexagon socket driver SW 2.5
Remove 11 screws [210].
Completely remove the two-part casing rear wall.
(ALS 256) Disconnect fan cable.
The installation is performed in reverse order.
[210] Fastening screws on rear wall of ALS 20X casing (small
picture: ALS 256).
[209] Label dispenser (ALS 20X) held in position via flange attached
to base plate