64
4.1 F
UNCTION
MENU
4.1 F
UNCTION
MENU
ALS
20X
256
On inhibit enter
function:
– „On entering inhibit“ means „after the inhibit signal
has been applied“
„Inhibit“ is an input signal, which supresses in-
coming start signals, what means, that start sig-
nals are being ignored as long as „Inhibit“ is ac-
tive. Nevertheless, incoming start signals are
being registered . Registered products are products,
which find themselves between start sensor and dis-
pensing edge.
– The function determines, how products are handled,
which already had passed the start sensor, as the
inhibit signal applied. The start signals triggered by
the products are registered in a queue.
– For details about the effect of the function, read
chapter “Impact of the inhibit signal” on page 14
– Settings: [„
Do regist starts
“, „Del regist strts“]
„Do registered starts“: The queue is not touched.
Registered products are labelled.
„Delete registered starts“: The queue is deleted.
Any started labelling cycle is finished.
On inhibit leave
function:
– „On leaving inhibit“ means „after the inhibit signal
stopped“
– The function determines, how products are handled,
which already had passed the start sensor, as the
inhibit signal stopped. The start signals triggered by
the products are registered in a queue.
– Settings: [„
Do regist starts
“, „Del regist strts“]
„Do registered starts“: Registered products are
being labelled as soon as the first product reaches
the dispensing edge.
„Delete registered starts“: The queue is deleted.
Incoming start signals are registered.
Materialend err
function:
– Refers to the internal OD control.
– Settings: [Disabled,
„
Mat.diam < x mm
“
]
– Setting range for x = [40,0…500,0]
– Default setting: x = 60
Deactivating the function:
Set x < 40.
Re-activating the function:
Press the
key.
Defines the diameter threshold for the material roll.
If the (calculated) material roll diameter is below the
threshold value, the following
status message
appears:
An additional material end error is caused, if no
unwinder rotation is detected during at least 600 mm
of material feeding:
Materialend warn
function:
– Refers to the internal OD control.
– Settings: [Disabled,
„
Mat.diam < x mm
“
]
– Setting range for x = [40,0…500,0]
– Default setting: x = 80
Deactivating the function:
Set x < 40.
Re-activating the function:
Press the
key.
Defines the diameter threshold for the material roll.
If the (calculated) material roll diameter is below the
threshold value, the following
warning
appears:
Rewinder full
function
Defines the maximum permissible diameter of the
wound backing paper on the backing paper
rewinder. If the diameter is exceeded, the following
status message appears:
– Setting range: [50…500] mm; Default setting:
202 mm
Ext. OD sensor
function:
– Refers to the external OD light barrier (option).
– Settings: [
Off
, Warning, Error]
Off: OD sensor is disabled.
Warning: OD sensor is enabled. If the outer roll
diameter is less than the critical value, the signal
output „Warning“ is activated.
Status num:
5071
Material end unw
Status num:
5072
Material end unw
ONLINE
Material low
Status num:
5064
Rewinder full