153
7.5 S
IGNAL
I
NTERFACE
ALS
20X
256
Signal response „Dispense End“
The signal „Dispense End“ can be controlled by the
functions in the
SIGNAL INTERFACE >PLC SIGNALS
sub-
menu.
A Duration of the dispensing operation [165A]
B Period setable via
SIGNAL INTERFACE >PLC SIGNALS >
Disp.end delay
[165B]
C Period setable via
SIGNAL INTERFACE >PLC SIGNALS >
End pulse width
[165C]
D Signal modes; setable via
SIGNAL INTERFACE >PLC
SIGNALS > End dispense mod
[165D]
– Modes
high/low active
: The signal is activated with
the start of dispensing. The duration is the sum of
the three periods A+B+C.
– Modes
high/low pulse
: The signal is activated after
dispensing ended and after period B and it lasts
period C [165C].
[165] Signal response of „Dispense End“.
dispense
high active
low active
high pulse
low pulse
D
B C
A